Specifications

6 - 34
6.11.12 Address designation by digital switch
Changes the positioning address of positioning data No.31 (buffer memory is 2306,
2307) designating in the unit of 1mm.
<Figure for operation explanation>
0
´“_)
50 100
150(mm)
2000 mm/min
<Positioning data>
No.
Operation
pattern
Control system
Axis to be
interpolated
Acceleration
time No.
Deceleration
time No.
Positioning
address
[
m]
Arc
address
[ m]
Command
speed
[mm/min]
Dwell
time
[ms]
M code
Positioning
data
comment
31 0: Completed
1: ABS linear 1
0:100 0:100 0.0 0.0 2000.00 0 0
32
33
<Sequence program>
X7(Registration of setting data)
Set mm to 0.1
μ
m
M7
D13DMOVP G2306
M7 X0AC
M7PLS
(BUSY)
Address write of axis 1
data No.31
D10=
D10BIN
D11BIN
D13D11D K10000
Positioning data No.
Positioning data
address set in the
unit of mm/min
Write the address that is set with the digital switch at "31"
*
K31
K3
K4X30
U0A\
Demonstration machine operation
1) Set the digital switch.
This example is
set as 123mm.
Set the positioning
data No.
01
30
Set the address between
25mm to 200mm.
03
21
X3F to X30
X2F to X20
2) Turning X7 ON sets the value of the 10000-multiplied setting value (unit: 0.1
m) as
the address of data No.31.
3) Turning X3 ON carries out the positioning for the designated address.
Change this column.
(Refer to Section 3.5.2.)
Repeat