Specifications

6 - 28
<Figure for operation explanation>
0
150(mm)
25 50
75
100
130
No.1
No.6
No.2 No.3 No.4 No.5
2000 mm/min
<Positioning data>
No.
Operation
pattern
Control system
Axis to be
interpolated
Acceleration
time No.
Deceleration
time No.
Positioning
address
[
m]
Arc
address
[ m]
Command
speed
[mm/min]
Dwell
time
[ms]
M code
Positioning
data
comment
1 0: Completed
1: ABS linear 1
0:100 0:100 50000.0 0.0 2000.00 0 0
2 0: Completed
1: ABS linear 1
0:100 0:100 75000.0 0.0 2000.00 0 0
3 0: Completed
1: ABS linear 1
0:100 0:100 100000.0 0.0 2000.00 0 0
4 0: Completed
1: ABS linear 1
0:100 0:100 130000.0 0.0 2000.00 0 0
5 0: Completed
1: ABS linear 1
0:100 0:100 150000.0 0.0 2000.00 0 0
6 0: Completed
1: ABS linear 1
0:100 0:100 25000.0 0.0 2000.00 0 0
7
8
9
10
Demonstration machine operation
1) Turning X2 ON carries out the positioning to the standby point of the positioning
data No.6 (25mm).
(The current value becomes 25000.0
m.)
2) The positioning data No. is designated by the digital switch.
000000 0
2
X2F to X20
X3F to X30
Positioning data No.
1
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
50 mm
2
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 75 mm
3
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 100 mm
4
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
130 mm
5
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
150 mm
6
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅ 25 mm
Positioning
address
3) Turning X3 ON carries out the designated positioning.
(The current value becomes the address of the designated data No.)
Repeat