Specifications

6 - 25
6.11.4 JOG operation of axis 1
Write the program that makes the machine perform forward run JOG while X4 is ON
and reverse run JOG while X5 is ON.
Lamp
Lamp
Axis 1 forward
run JOG
Y0A9
X4 Y0A9
X5 Y0A8
Y75
DMOVP
K100000
Y74
Y0A8
G1518
DMOVP
Inter
lock
(Axis 1 forward run JOG command)
(Axis 1 reverse run JOG command)
Inching movement
amount 0.0 m
Axis 1 reverse
run JOG
K100000
U0A\
Axis 1 JOG speed
1000 mm/min
X6
X6
G1517MOVP K0
U0A\
G1517
MOVP
K1000
U0A\
G1518
U0A\
Axis 1 JOG speed
1000 mm/min
MOVP
K0
G1517
U0A\
Inching movement
amount 0.0 m
Inter
lock
Inching movement
amount 100.0 m
Demonstration machine operation
1) Turning X4 ON starts the forward run and turning OFF stops it.
2) Turning X5 ON starts the reverse run and turning OFF stops it.
3) Turning X4 ON with X6 ON once makes a 100.0
m inching movement in the
forward direction.
REFERENCE
The inching operation can be carried out by setting the inching movement amount into the
JOG operation program.
Axis 1 Axis 2 Axis 3 Axis 4
Inching movement amount buffer
memory
1517 1617 1717 1817