Specifications

6 - 22
Practice question (2) Answer
Project name
B
Y0A9
Axis 1 reverse
run JOG
Y0A8
Axis 1 forward
run JOG
X4(Axis 1 forward run JOG)
DMOVP
G1518
K100000
U0A\
Axis 1 JOG
speed
1000 mm/min
X5(Axis 1 reverse run JOG)
DMOVP
K100000
G1518
U0A\
Axis 1 JOG
speed
1000 mm/min
Reference: When designating the JOG speed by the sequence program, designate
100 times as much as the actual value since the unit is [
10
-2
mm/min].
6.11 Sample Sequence Program
Practice with the sequence program used as a sample.
For a preparation, read out the sequence program from the text FD and then write it to
the PLC CPU.
Operation of peripheral devices
1) Start GPPW on the peripheral device.
2) Insert the QD75 text FD into the FDD and click
(the [Project] [Open project]
menu).
Open the project named "X" from the A drive on the dialog box to open projects.
3) Write the parameter and the main sequence program to the PLC CPU, using
(the [Online]
[Write to PLC]).
PLC CPU is STOP
(Click the Param+Prog button on the PLC write dialog box, then click the
Execute
button.)
4) Save the project to user FD.
Remove the QD75 text FD from the FDD and insert the formatted user FD.
Click the [Project]
[Save as Project] menu.
Set "Drive/Path" and "Project name" and save the project.
5) Reset the PLC CPU once, and then put into the RUN state.
6) Monitor GPPW by the peripheral device.
Click
(the [Online] [Monitor] [Monitor mode] menu).