Specifications
5 - 16
[Monitoring operation]
1) Double-click the "Monitor"
"Operation
monitor" icon on the project toolbar.
2) The operation monitor window appears.
To display the feed present value, axis feed
speed, axis status and positioning data being
executed of each axis, click the
Monitor Start
button.
To monitor the details of the settings and
status of the QD75, click the [History] / [Signal]
/ [#1 Operation status] to [#4 Operation status]
buttons on the operation monitor window.
3) History monitor, Signal monitor or Operation
dialog box appears. Click the tab on each
dialog box to display items to monitor.
(The left screen is the X Device monitor
screen of the Signal monitor dialog box.)
4) Click the Monitor Stop
button on the
operation monitor window to terminate
monitoring.
<Monitor target by dialog box>
Dialog box name Monitor target (tab name) Description
Error history Occurrence time, axis and code of the latest 16 errors.
Warning history Occurrence time, axis and code of the latest 16 warnings.
History monitor
Start history Time and normal/error judgment of the latest 16 axis starts.
X device ON/OFF status of QD75 input signal.
Y device ON/OFF status of QD75 output signal.
External I/O signal ON/OFF status of external input/output signal to QD75.
Signal monitor
Status signal ON/OFF status of QD75 status signal.
Axis control data Details of axis while positioning control is being executed.
Speed-position control Details while speed or speed-position switching control is
being executed.
Position-speed control Details while position-speed switching control is being
executed.
OPR control Settings and signal status relevant to OPR control.
Operation monitor
JOG/manual pulse
generator
Settings and status of JOG operation and manual pulse
generator.