Specifications
5 - 9
5.5.1 Basic parameter and OPR basic parameter setting
Set the parameters according to the devices to be used and the control details.
In the procedure below, the initial values (default values) are used except some items.
1) Double-click the "Edit" icon.
2) Double-click the "Parameter data" icon.
3) The parameter edit window appears.
Enter "20000" in the Axis #1 column of Basic
parameter2 "Speed limit".
4) Scroll down the parameter edit window and set
the Axis #1 OPR basic parameter as follows.
"OPR direction" ............ 1: Reverse direction
(Address decreases)
"OPR speed" ................ 5000
"Creep speed" .............. 1000