Some transistor output modules use transistors provided with
short-circuit protection to protect the internal circuits of output
modules from being burnt out due to a wiring mistake or external
device failure.
To reduce the risk of program data erasure due to battery failure,
built-in flash ROMs are built in all CPU types so there is no need to
add a memory card to store programs into ROM.
During adjustment of machinery/equipment, partial correction to a
program must sometimes be made without stopping sequence
processing. The Q series enables online correction to a program
(write during RUN). Online program correction can be made to not
only the CPU directly connected but also any CPU via a network
system (Ethernet, MELSECNET/H, CC-Link). Online rewriting of a
program file is also possible (high-performance model QCPUs
only), exhibiting the high performance of program correction during
adjustment.
The Q series CPU modules include an RS-232 port operable at
max.115.2kbps as standard. A USB port is also installed which is
used with Windows
®
personal computers
(Q00J/Q00/Q01/Q02CPU is equipped with RS-232 only). These
high-speed programming ports have achieved much shorter
program transfer time and faster monitoring, increasing the
adjustment efficiency of machinery/equipment .
The high-performance QCPU allows program, parameter and other
files stored in a PC card to be transferred automatically to the
program memory of a CPU and its contents to be written
automatically to the built-in standard ROM. You can send a
memory card to a field site, where CPU programs can be modified
without using programming software.
GX Developer allows online programming and monitoring and
testing operations to be performed with the Q series PLCs installed
at remote locations. Connections to the Q series PLCs connected
to Ethernet can be made via Ethernet, and connections to the
PLCs connected with modems can be made via the telephone
line/ISDN line.
If a fault occurs in the system, the mobile computer or personal
computer is automatically notified of the system status by E-mail.
This enables you to monitor the PLC devices with comments and
run primary diagnostics if you are at a remote location. The GT
SoftGOT HMI software for personal computer or GX Remote
Service-I remote maintenance tool has to be installed in the personal
computer (Web server), which is connected to the target PLC.
26k-step program and parameter write time (s)
Q25HCPU(USB)
Q25HCPU(RS-232)
Q3ACPU
A4UCPU
12
30
0 102030
40 50 60 70 80
86
94
90 100
Note1: USB is supported by Windows
®
98/2000/Me only.
Windows
®
2000/Me is supported by GX Developer Ver. 7 or later.
Telephone line
Modem
Router
Modem
Program
file
Parameter
file
Program
memory
CPU
Standard ROM
Memory card
In the field
No necessity
of special DIP switch
settings
Here are the following two ways to utilize the conventional AnS series hardware.
1) Select the basic model/high-performance model CPU to make the most of the performance and functions of the Q series.
2) Select the A mode model CPU to use the conventional AnS series hardware configuration in order to improve the performance of only the
CPU.
Note 6: Since some instructions are unusable, refer to the Q series data
book for details.
Note 7: The A mode model does not require programs to be converted.
Q series programs are required to use the Q series. As the
conversion tool is available to convert A/QnA series programs into
Q series programs, transition to the Q series can be made easily
without wasting your program assets. (Note 6)(Note 7)
Internet
PULL
USB
Q02HCPU
MODE
RUN
ERR
USER
BAT
BOOT
RS-232
PULL
POWER
Q61P-A1
SY. ENC1
SY. ENC1
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Q172Q172
Q172EX
SY. ENC TREN
QX40
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
QX40
1
2
1
2
Personal computer
(e.g. Web browser)
Mobile computer
Q series PLC
GX RemoteService-I
or
GT SoftGOT
(Web server)
Remote location
Factory
Note 3: GT SoftGOT allows the personal computer to display the same data
and perform the same operations as on the GOT900.
E-mail
GX Developer
GX Developer
GX Developer
Alarm
Maintenance
Alarm
Maintenance
Note2: The time may be longer than above depending on the
performance of the personal computer and the conditions of
communication with other devices.
Note 4:
Some modules for the AnS series, e.g. MELSECNET/II and MELSECNET/B, are not usable or have operating restrictions. Check details in the Q series data book.
Note 5: Only the RS-232 port may be used for connection with the GOT-F900 series.
Features
CPU type
Usable programs
Q00JCPU, Q00CPU, Q01CPU
Q series programs
Various functions introduced in this catalog are all usable.
(With the exception of the functions indicated
"High-performance model")
For Q series modules: Q3 B, Q6 B, Q5 B
For Q series modules:
Q61P-A1/A2, Q6 P
For Q series
For Q series
Q02CPU, Q02HCPU, Q06HCPU,
Q12HCPU, Q25HCPU
Q series programs
Various functions introduced in
this catalog are all usable.
For Q series modules: Q3 B, Q6 B, Q5 B
For A series modules: QA65B, QA1S6 B
For Q series modules: Q61P-A1/A2, Q6 P
For A series modules: A6 P, A1S6 P
For Q series and AnS series (Note 4)
For Q series
Q02CPU-A, Q02HCPU-A, Q06HCPU-A
A series programs
Only the functions usable in the A series can be used,
and various functions introduced in this catalog are
not usable with the exception of some functions.
QA1S3 B, QA1S6 B
A1S6 P
For AnS series
For A series
Usable base units
Usable power supply
modules
Usable functions
System configuration
example
Usable peripheral devices
Usable GOT (Note 5)
Usable I/O, special,
network and other modules
Designed to configure a compact system
by combining the basic model QCPU
and other Q series modules.
A900/F900 series GOT
Connection method: CPU RS-232,
serial communication module,
MELSECNET/10, CC-Link, Ethernet, bus
A900/F900 series GOT
Connection method: CPU RS-232,
serial communication module,
MELSECNET/10, CC-Link, Ethernet, bus
A800/900/F900 series GOT
Connection method: CPU RS-232,
computer link module, MELSECNET/ /10/B,
CC-Link,Ethernet (bus unconnectable)
Designed to make the most of the inherent
functions and performance capabilities of the
Q series by combining the high-performance
model QCPU and other Q series modules.
If the appropriate module is not available
from the Q series, you can use the AnS
series module.
Designed for the customer who is using the AnS
series to improve only the processing
performance of the CPU without changing its
programs and hardware. Among the current AnS
series hardware, you only need to change the
CPU module, bases and extension cables to
increase the processing speed.
As required, Ans power
supply, I/O, special and
network modules may be
used in extension base.
Use QA1S6 B with AnS
modules. As a matter of
course, Q series modules
can be added. Use Q6 B
/Q5 Bwith Q series
modules.
High-performance model QCPU
and Q series modules
Power supply, I/O, special and
network modules are all for Ans
A mode CPU
Basic Model High-performance Model A Mode
Extension base Q6 B
/Q5 B is used. (QA65B
or QA1S6 B is unusable.)
Basic model QCPU
and Q series modules
Main base
Q3 B is used
(Not needed for
Q00JCPU)
Main base
Q3 B is used
Main base
QA1S3 B is used
Extension cable
for Q series
is used
Extension cable
for Q series
is used
Q series-compatible
software is used on
Windows
®
personal
computer.
(SW7D5C-GPPW or later
is usable.)Use QC30R2
cable.
Q series-compatible
software is used on
Windows
®
personal
computer.
(SW4D5C-GPPW or later
is usable.)Use QC30R2
cable.
Extension base
QA1S6 B is used
Extension cable
for Q series
is used
A series-compatible software is
used on Windows
®
personal
computer, or A6GPP or similar A
series peripheral device, e.g.
A8PUJ and the like may be used.
Note that since peripheral port of A
mode CPU is RS-232, RS-232/422
conversion cable is needed for use
of A series-compatible device of
RS-422 specifications.
.
Device monitorDevice monitor
.
Primary diagnosticsPrimary diagnostics
.
Device monitor
.
Primary diagnostics
Line A conditions
Y0 Line A conveyor stop
Y0
T100 Watch timer
T100
D0 Production count
100 D0
http://. .
/index
A fault occurred in Line
A. Check the system
status.
Increased Speed of Programming Port
Automatic Writing to Standard ROM by PC Card
Short-Circuit Protection
Built-In Standard ROM
Online Program Correction
Remote Programming
Remote Maintenance
Utilization of Hardware Assets
Utilization of Software Assets
24
UTILIZATION OF EXISTING ASSETS
25
EASY MAINTENANCE