User`s manual

App - 17 App - 17
MELSEC-Q
APPENDIX
Buffer memory address
Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Axis 7 Axis 8
Item Memory area
50 150 250 350 450 550 650 750
Cd. 1
Axis error reset
51 151 251 351 451 551 651 751
Cd. 2
OPR request flag OFF request
52 152 252 352 452 552 652 752
Cd. 3
Start method
53 153 253 353 453 553 653 753
Cd. 4
Restart request
54 154 254 354 454 554 654 754
Cd. 5
Speed-position switching request
55 155 255 355 455 555 655 755
Cd. 6
Speed change request
56
57
156
157
256
257
356
357
456
457
556
557
656
657
756
757
Cd. 7
New speed value
58 158 258 358 458 558 658 758
Cd. 8
ACC/DEC time at speed change
59 159 259 359 459 559 659 759
Cd. 9
DEC/STOP time at speed change
Axis control data
60
to
69
160
to
169
260
to
269
360
to
369
460
to
469
560
to
569
660
to
669
760
to
769
Reserved (Cannot be used)
70
71
170
171
270
271
370
371
470
471
570
571
670
671
770
771
Md. 1
Current feed value
72
73
172
173
272
273
372
373
472
473
572
573
672
673
772
773
Md. 2
Movement amount after near-point dog ON
74
75
174
175
274
275
374
375
474
475
574
575
674
675
774
775
Md. 3
Current speed
76 176 276 376 476 576 676 776
Md. 4
Axis operation status
77 177 277 377 477 577 677 777
Md. 5
Axis error code
78 178 278 378 478 578 678 778
Md. 6
Axis warning code
79 179 279 379 479 579 679 779
Md. 7
Status
80 180 280 380 480 580 680 780
Md. 8
External I/O signal
81 181 281 381 481 581 681 781
Md. 9
Executing positioning data No.
Axis monitor data
82
to
99
182
to
199
282
to
299
382
to
399
482
to
499
582
to
599
682
to
699
782
to
799
Reserved (Cannot be used)