Operator`s manual

FEATURES AND CONTROLS
- 6 -
10a
1. Fuel Tank Cap
2. Fuel Tank
3. Fuel Gauge (oponal)
4. Fuel Tank Breathing Valve
5. Engine Choke Lever
6. Fuel Shut-off
7. Air Filter
8. Recoil Starter
9. Oil Gauge
10. Engine Shut-off
10a. Hour Meter
(Only for MBG5500/7000/
MBG7000X)
11. 120 V, 20 Ampere Duplex
Receptacle
or GFCI (oponal)
12. AC Protector
(MBG5500, MBG6500 Only)
13. Circuit Breaker
14. 120/240 V, 20 Ampere
Twist lock Receptacle
15. Ground Terminal
16. Oil Drain Plug
17. Muffler
18. Spark Arrester
19. Carbon Canister
Inspecon Window
FULL
EMPTY
Fuel Gauge (3)
(oponal)
120 V, 20 Ampere Duplex Receptacle (11)
20 amps of current may be drawn from each half of
the receptacle. However, total power drawn must
be kept within nameplate rangs. These receptacles
may be used along with the twist lock receptacle
provided the generator is not overloaded.
120V, 20 Ampere GFCI Duplex Receptacle (oponal)
If your generator comes with GFCI duplex
receptacle, aer starng the engine, check the GFCI
for proper funconing by the following test
Push TEST buon, The RESET buon will pop out. Power is now
off at the outlets protected by the GFCI, indicang that the device
is funconing properly.
If TRIP does not appear when tesng, do not use the generator.
Call a qualified electrician.
To restore power, push RESET buon.
WARNING
If the RESET buon pops out during operaon, stop the generator
immediately and call a qualified electrician for checking generator
and the appliances.
The duplex 120V receptacle is protected by a GFCI. GFCI shuts off
the output current from the duplex 120V receptacle when a
ground fault occurs in the generator or the appliance. Please note
that other receptacles are not protected by GFCI.
CAUTION
procedure:
GFCI Duplex Receptacle