Operator`s manual

- 13 -
NOTE
TROUBLE SHOOTING
Condion Cause Correcve Acon
Engine won't
start
Low engine
output
Engine runs
erracally
Insucient
compression
Loose spark plug Tighten plug properly
Loose cylinder head bolt Tighten bolt properly
Damaged gasket Replace gasket
Sucient
compression
No fuel
supplied to
combuson
chamber
1. Insucient pulling speed for
starng rope
Pull rope sharply
2. Foreign maer in fuel tank Clean tank
3. Clogged fuel line Clean fuel line
4. No fuel in tank Rell tank
5. Fuel switch not open Open valve
Combuson
chamber
supplied with
fuel
1. Spark plug dirty with carbon
or wet with fuel
Remove carbon or wipe out spark
plug
2. Damaged spark plug Replace spark plug
3. Faulty Magneto
Consult the Service Center
4. Improper adjustment of
carburetor
Improper grade of fuel used
Make sure the proper grade of fuel
has been used
Overloading
Make sure you haven’t plugged in too
many devices. Check fan
Overheang
Lower oil level Add sucient oil as specied.
Engine ON, yet
no AC output
Tripped circuit breaker Reset
Poor connecon or faulty lead Check and repair
Broken receptacle
Contact the Service Center
Faulty circuit breaker
Generator problem
If your generator experiences a low engine oil condion, the engine will automacally shut off. Please check the oil first if you cannot start
the generator.