Operator`s manual

MAINTENANCE
- 11 -
1. Maintenance Schedule
CAUTION
To prevent accidental starng, always remove the spark plug or
cable from the spark plug before maintaining the generator or
engine.
ITEM
REMARKS
DAILY
Before Operaon
INITIAL
25HR
EVERY
50HR
EVERY
100HR
Spark Plug
Check condion adjust gap and clean. Replace if
necessary
Engine Oil
Check oil level
Replace
Air Filter Clean, replace if necessary
Fuel Filter Clean and adjust. Replace if necessary
Fuel Hose
Check fuel hose for crack or damage. Replace if
necessary
Exhaust
System
Check for leakage. Reghten or
replace gasket if necessary
Check muffler screen. Clean/replace if
necessary
Carburetor check choke operaon
Cooling
System
Check fan damage
Starng
System
Check recoil starter operaon
Fings
Fasteners
Check all fings and
fasteners correct if necessary