Specifications

55
(2) Recommended circuit
Relay-driven circuit
CN5
4
9
3
2
1
Z1 L1
Z2 L2
Z1
Z2
EB-50
Brown
Diode
*2
Max.
10 m (32 ft)
L1: ON indicator
L2: Error indicator
External power supply
*1
Black
Green
Use relays Z1 and Z2 that meet the following specifications.
Operation coil
Rated voltage: 12 or 24 VDC
Power consumption: Max. 0.9 W
*1 Select an external power supply suitable for the relays
used. (12 or 24 VDC)
Connect the external power supply in the correct
polarity to input and output the signals.
Connect
1
(shown in the figure at left) to the negative
side.
*2 Use a diode at both ends of the relay coils.
Important
Be sure to use an external power supply (12 or 24
VDC) to avoid malfunctions.
Connect the external power supply in the correct
polarity to avoid malfunctions.
Do not connect the external power supply without
relays being connected to the controller (no load).
Note
The relays, lamps, external power supply, diodes, and extension cables are field supplied.
The total length of the lead wire and extension cable should not exceed 10 m (32 ft). (Use an extension cable of 0.3
mm
2
or thicker.)
Each element will turn on during operation and when an error occurs.