Specifications
28
Method 2: Installation using DIN rail
1. Have a metal control box ready. (Minimum steel thickness: 1 mm (3/64 in))
2. Attach the supplied two DIN rail attachments to the EB-50 with the supplied M3 screws. (Fig. 5-4)
3. Properly mount the EB-50 on the DIN rail vertically (Fig. 5-5 and Fig. 5-6), taking into consideration the installation space (Fig.
5-2).
Fig. 5-4 Fig. 5-5
up
M3 (6 mm (1/4 in))
DIN rail attachments
Note
● Each DIN rail attachment must be fixed to the EB-50 with four M3 screws.
● To secure the strength, the screw pitch must be 200 mm (7-7/8 in) or less when DIN rail is mounted to the metal control
box.
● The surface on which the EB-50 will be installed needs to be strong enough to support its weight (1.0 kg (3 lbs) each).
● Do not install the EB-50 where it may receive vibration. Use studs to fix the EB-50 as necessary.