Technical Manual
49
Maintenance
Button operation
[
2
]
[
1
]
Select "Maintenance" from the Main menu (refer to page 19), and press
the
button.
Select "3D i-See sensor" with the F1
or F2 button, and press the but-
ton.
Select "Air distribution" with the F1
or F2 button, and press the but-
ton.
F1 F2 F3 F4
3D i-See sensor
Cursor
Setting display:
Air distribution
Energy saving option
Seasonal airflow
F1 F2 F3 F4
Air distribution
Input display:
Cur. Address Check
Ref. address
Unit No.
Identify unit Check button
Move the cursor to "Ref. address", "Unit No." or "Operation" with the F1
button to select.
Select the refrigerant address and the unit number for the units to whose
vanes are to be fixed, with the F2
or F3 button, and press the button.
• Ref. address: Refrigerant address
• Unit No.: 1, 2, 3, 4
Press the
F4
button to confirm the unit.
The vane of only the target indoor unit is pointing downward.
<Confirmation of target unit>
If the unit being set is unknown, make the setting and then press the
F4
but-
ton to conrm.
The air conditioner which is blowing downward is the target air conditioner.
Air distribution