M-Series Filter Chart

Indoor Unit Filter_MSZ-A-NA-1 - Form# 201401
Specications are subject to change without notice.
©2014 Mitsubishi Electric US, Inc.
10–M-Series–MSZ-A-NA-1
M-SERIES
WALL-MOUNTED
MSZ-A-NA-1
Unit / Model Number MSZ-A09NA-1 MSZ-A12NA-1 MSZ-A15NA-1 MSZ-A17NA-1
Standard Filter Provided
(Yes/No)
Yes Yes Yes Yes
Name/Type of Filter Anti-Allergy Enzyme Filter Anti-Allergy Enzyme Filter Anti-Allergy Enzyme Filter Anti-Allergy Enzyme Filter
If provided,
Filter Part Number
(and Quantitiy needed)
MAC-415FT-E MAC-415FT-E MAC-415FT-E MAC-415FT-E
Specication Gravimetric 25% Gravimetric 25% Gravimetric 25% Gravimetric 25%
Particle Size (μm)
3
3.0 - 5.0 3.0 - 5.0 3.0 - 5.0 3.0 - 5.0
Filter Efciency 0.46 0.46 0.46 0.46
MERV 6 6 6 6
Service
Size [L x W x D]
Details
3.0-10.0 μm more than
35% - 49.9%
3.0-10.0 μm more than
35% - 49.9%
3.0-10.0 μm more than
35% - 49.9%
3.0-10.0 μm more than
35% - 49.9%
Alternate Filter
Available?
(- See notes column for
more info)
Yes Yes Yes Yes
Alternate Filter - Name
and Description
Catechin Air Filter Catechin Air Filter Catechin Air Filter Catechin Air Filter
Alternate Filter - Model
Number
E12 915 100 (Left)
E12 916 100 (Right)
E12 915 100 (Left)
E12 916 100 (Right)
E12 915 100 (Left)
E12 916 100 (Right)
E12 915 100 (Left)
E12 916 100 (Right)
Filter Box Required? No No No No
Filter Box Model Number - - - -
Alternate Filter -
Specication
Gravimetric 25% Gravimetric 25% Gravimetric 25% Gravimetric 25%
Alternate Filter -
Particle Size (μm)
3
6.6 - 8.6 6.6 - 8.6 6.6 - 8.6 6.6 - 8.6
Alternate Filter -
Filter Efciency
0.25 0.25 0.25 0.25
Alternate Filter - MERV 1 to 4 1 to 4 1 to 4 1 to 4
Alternate Filter - Service
Alternate Filter - Size
[L x W x D]
Alternate Filter - Details 3.0-10.0 μm less than 20% 3.0-10.0 μm less than 20% 3.0-10.0 μm less than 20% 3.0-10.0 μm less than 20%
Notes
Location of Spec Sheet
for Alternate Filter
- - - -
Indoor Unit Filter Chart