Operation Manual

EV charging cable
3-22 General information/Charging
3
: Illuminates : Blinking : Not illuminated
POWER
FAULT
CHARGING
Operating condition
Every time the charging cable plug (C) is connected to an outlet, all indicator lights illuminate
for 1/2 second, then go out.
After initial processing is completed, when the regular charge connector is not connected to the
charge port, or the regular charge connector is connected to the charge port but charging is not
being performed.
While the main drive lithium-ion battery is being charged
When the ground cable is disconnected
Check the grounding of the outlet being used. If the outlet is properly grounded, contact a certi-
fied i-MiEV dealer.
When charging is completed.
POWER
FAULT
CHARGING
Abnormal operating condition and corrective action
When an electric leakage occurs or the EV charging cable malfunctions.
Stop use immediately and contact a certified i-MiEV dealer.
When the EV charging cable malfunctions.
Stop use immediately and contact a certified i-MiEV dealer.
If the control box indicator light does not illuminate after connecting the charging cable plug to
the outlet, check the circuit breaker for the outlet. If the breaker has tripped, the circuit may not
be suitable for use with EV charging cable. You should have a licensed electrician inspect and
repair the electrical circuit. If the breaker is not tripped, stop using the EV charging cable and
contact a certified i-MiEV dealer.
BK0209800US.book 22 ページ 2014年1月14日 火曜日 午前9時26分