User`s manual
Table Of Contents
- SAFETY PRECAUTIONS
- CONDITIONS OF USE FOR THE PRODUCT
- REVISIONS
- INTRODUCTION
- CONTENTS
- ABOUT MANUALS
- HOW TO USE THIS MANUAL
- ABOUT THE GENERIC TERMS AND ABBREVIATIONS
- PACKING LIST
- 1. OVERVIEW
- 2. SYSTEM CONFIGURATION
- 3. FUNCTION LIST
- 4. INSTALLATION AND UNINSTALLATION
- 5. SCREEN MAKEUP AND BASIC OPERATIONS
- 6. PROJECT CREATION
- 7. SYSTEM CHECKING FROM PERIPHERAL DEVICE
- 8. DATA SETTING
- 9. WRITING TO/READING OF/VERIFICATION OF POSITIONING MODULE DATA
- 10. POSITIONING DEBUGGING
- 11. USEFUL FUNCTIONS
- APPENDIX
- Appendix 1 Read from Module/Write to Module Reference Processing Times
- Appendix 2 Restrictions Depending on Function Version of QD75
- Appendix 3 Functions Added to/Changed from the Previous Versions
- Appendix 4 Uninstalling the License Key FD
- Appendix 5 Parameter Names Shown in GX Configurator-QP Screens and Manuals
- INDEX

6 - 5 6 - 5
MELSOFT
6. PROJECT CREATION
HELPFUL OPERATION (PART 2)
When utilizing the data written to the QD75/LD75/LD77 to create a new project,
perform the following operation.
1. Set the Module type, project save path, project name and project title in the
New Project dialog box.
2. Click the "New Project read to module" check box.
3. Click the "OK" button.
4. Click the "OK" button in the instruction dialog box.
5. Set the interface, I/O address and others in the Connection setup dialog box
(refer to Section 7.1).
6. Click the "OK" button.
7. Set the type and range of the data to be read in the Read from module dialog
box (refer to Section 9.1).
8. Click the "OK" button to read the positioning data, block start data and
parameters in the specified range from the QD75/LD75/LD77.
<New module data reading procedure>
New project creation
Instruction is given to indicate
which model has precedence.
Connection setup (refer to Section 7.1)
Read from module (refer to Section 9.1)
When New Project read to module is performed for new project creation, the
QD75/LD75/LD77 connected has precedence if the QD75/LD75/LD77 model of the
project differs from the QD75/LD75/LD77 model connected.
After completion of reading, choose the [Project]
[Change module type] menu to
change the model. (Refer to Section 11.1.2.)