(From the preceding page)
Step 5: Set and write data to the positioning module. Refer To
• Set the parameters appropriate for the positioning control system and control.
Set the servo parameters appropriate for the specifications of the servo amplifiers and motors used.
(Only QD75M, QD75MH, and LD77)
• Set the positioning data and M code comments.
• Check the positioning data on the simulation screen.
• Make the corresponding setting if block start data and/or condition data is required.
• Make error check to check the parameters, servo parameters, positioning data and block start
data settings.
Chapter 8
• Write, read or verity the set data on the project. Chapter 9
Step 6: Perform test operation and check and adjust the settings. Refer To
• Make online error check to recheck the settings of the parameters, servo parameters, positioning
data and block start data written to the QD75/LD75/LD77.
• Check positioning control and test on the monitor screen.
• Set the positioning data and block start data, and perform test operation.
• Make present value change test, speed change test, OPR test, JOG operation test and MPG
operation test to check the parameters, addresses, axis speeds, etc.
Chapter 10
Step 7: Positioning control system operation Refer To
• Operate the positioning control system with the programmable controller CPU program.