User`s manual
Table Of Contents
- SAFETY PRECAUTIONS
- CONDITIONS OF USE FOR THE PRODUCT
- REVISIONS
- INTRODUCTION
- CONTENTS
- ABOUT MANUALS
- HOW TO USE THIS MANUAL
- ABOUT THE GENERIC TERMS AND ABBREVIATIONS
- PACKING LIST
- 1. OVERVIEW
- 2. SYSTEM CONFIGURATION
- 3. FUNCTION LIST
- 4. INSTALLATION AND UNINSTALLATION
- 5. SCREEN MAKEUP AND BASIC OPERATIONS
- 6. PROJECT CREATION
- 7. SYSTEM CHECKING FROM PERIPHERAL DEVICE
- 8. DATA SETTING
- 9. WRITING TO/READING OF/VERIFICATION OF POSITIONING MODULE DATA
- 10. POSITIONING DEBUGGING
- 11. USEFUL FUNCTIONS
- APPENDIX
- Appendix 1 Read from Module/Write to Module Reference Processing Times
- Appendix 2 Restrictions Depending on Function Version of QD75
- Appendix 3 Functions Added to/Changed from the Previous Versions
- Appendix 4 Uninstalling the License Key FD
- Appendix 5 Parameter Names Shown in GX Configurator-QP Screens and Manuals
- INDEX

11 - 19 11 - 19
MELSOFT
11. USEFUL FUNCTIONS
11.3.2 Block start copy
PURPOS
E
Using the block start copy function, copy the block start data to the other blocks.
The block start copy function is performed to copy data between blocks in the
same project.
BASIC OPERATIO
N
1. Display the block start data edit window (refer to Section 8.5).
2. Click the [Edit]
[Block start copy] menu.
3. Set the block No. of the copy source and the block No. of the copy destination.
4. Click the "OK" button.
DISPLAY/SETTING SCREE
N
DISPLAY/SETTING DATA
Item Description
Copy source block No. Choose the copy axis and the block No. of the copy source.
Copy destination block No.
Set the copy axis and the block No. of the copy destination.
Multiple blocks can be set at the same time.
"OK" button Click this button to copy the data.