User`s manual

Table Of Contents
11 - 7 11 - 7
MELSOFT
11. USEFUL FUNCTIONS
[Intelligent function module utility]
DISPLAY/SETTING DATA
Item Description
Project save path
Choose the save destination of the GX Developer project to which auto refresh setting will be
made.
GX Developer project Choose the GX Developer project to which auto refresh setting will be made.
Start I/O No. Set the first I/O No. (I/O address) of the QD75/LD75/LD77.
Package name Choose the positioning module.
Module model name Choose the model of the QD75/LD75/LD77.
Intelligent function module
parameter setting module
Shows the module to which the initial setting or auto refresh setting has been made in the
intelligent function module utility.
"Auto refresh" button Click this button to show the auto refresh setting dialog box.
"Delete" button
Click this button to make deletion from the intelligent function module parameter setting
module.
PLC side Device
Set the programmable controller side devices to be automatically refreshed for the
QD75/LD75/LD77 items.
Data is automatically refreshed between the set devices and QD75/LD75/LD77 buffer
memory.
"Make text file" button
Used to save the auto refresh settings as text data.
Clicking this button shows the text file creation dialog box, where you set the save
destination drive/path and file name.
"End setup" button Click this button to register the auto refresh setting and close the dialog box.