User`s manual

Table Of Contents
11 - 5 11 - 5
MELSOFT
11. USEFUL FUNCTIONS
11.1.3 Intelligent function utility
PURPOS
E
Make setting to read the following data automatically from the QD75/LD75/LD77
buffer memory to the QCPU/LCPU devices (e.g. data registers).
The set data are stored in the intelligent function module parameters of the GX
Developer project.
• Feed present value • Machine feed value • Feed speed
• Error No. • Warning No. • Enable M code
• Axis operating status
Auto refresh allows the above data of the QD75/LD75/LD77 to be imported to the
QCPU/LCPU without creation of a program.
BASIC OPERATIO
N
1. Set the required project as the active project. (Refer to Section 5.2.)
2. Click the [Tool]
[Intelligent function utility] menu.
3. Choose the target GX Developer project in the GX Developer project dialog box.
4. The intelligent function module utility starts.
5. Set Start I/O No., Package name and Module model name.
6. Click the "Auto refresh" button.
7. Assign the programmable controller CPU side devices to the auto refresh items
in the Auto refresh setting dialog box.
8. Click the "End setup" button.
9. Click the "Exit" button in the Intelligent function module utility.
10. Click the "Yes" button in the intelligent function module parameter save
confirmation dialog box.
The intelligent function module utility can be started to execute the auto refresh
setting in GX Developer.
To start the intelligent function module utility in GX Developer, click [Tools]
[Intelligent function utility] menu
"Auto refresh" button.
Then, follow the above procedure of the basic operation from 5 to 10 to set the
auto refresh.