User`s manual
Table Of Contents
- SAFETY PRECAUTIONS
- CONDITIONS OF USE FOR THE PRODUCT
- REVISIONS
- INTRODUCTION
- CONTENTS
- ABOUT MANUALS
- HOW TO USE THIS MANUAL
- ABOUT THE GENERIC TERMS AND ABBREVIATIONS
- PACKING LIST
- 1. OVERVIEW
- 2. SYSTEM CONFIGURATION
- 3. FUNCTION LIST
- 4. INSTALLATION AND UNINSTALLATION
- 5. SCREEN MAKEUP AND BASIC OPERATIONS
- 6. PROJECT CREATION
- 7. SYSTEM CHECKING FROM PERIPHERAL DEVICE
- 8. DATA SETTING
- 9. WRITING TO/READING OF/VERIFICATION OF POSITIONING MODULE DATA
- 10. POSITIONING DEBUGGING
- 11. USEFUL FUNCTIONS
- APPENDIX
- Appendix 1 Read from Module/Write to Module Reference Processing Times
- Appendix 2 Restrictions Depending on Function Version of QD75
- Appendix 3 Functions Added to/Changed from the Previous Versions
- Appendix 4 Uninstalling the License Key FD
- Appendix 5 Parameter Names Shown in GX Configurator-QP Screens and Manuals
- INDEX

10 - 21 10 - 21
MELSOFT
10. POSITIONING DEBUGGING
Item Description
Torque control storing
value
Shows the torque limit value or new torque value valid for the running servo motor.
Buffer memory address (Axis #1): 826
Revival load proportion
Shows the regenerative load factor relative the permissible value of the regenerative brake
resistor selected in the servo basic parameter (refer to Section 8.2).
Buffer memory address (Axis #1): 878
Execution load proportion
Shows the load factor relative to the rated torque.
Buffer memory address (Axis #1): 879
Peak load proportion
Shows the peak load factor relative to the rated torque.
Buffer memory address (Axis #1): 880
DISPLAY/SETTING SCREE
N
(1) QD75M
[Servo parameter setting contents]