User`s manual

Table Of Contents
10 - 18 10 - 18
MELSOFT
10. POSITIONING DEBUGGING
DISPLAY/SETTING SCREE
N
[JOG/MPG monitor]
(Screen example: Axis #1 operation monitor screen)
DISPLAY/SETTING DATA
Item Description
Foward JOG
Reverse JOG
Indicates the direction during JOG operation in the program.
JOG speed
Indicates the axis speed during JOG operation in the program.
Buffer memory address (Axis #1): 1518, 1519
JOG speed limit value
Indicates the JOG operation limit value set in the extended parameters 2.
Buffer memory address (Axis #1): 48, 49
JOG ACC time
JOG DEC time
Shows the acceleration time and deceleration time set in the extended parameters 2.
Buffer memory address (Axis #1): 50 (JOG ACC time), 51 (JOG DEC time)
Enable/Disable
Shows if manual pulse operation is allowed or not.
Permission setting in the test mode from the peripheral device is not displayed.
Buffer memory address (Axis #1): 1524
Manual pulse input mode
Shows the MPG pulse input mode set in the extended parameters 1.
Buffer memory address (Axis #1): 33
Manual pulse multiplier
Indicates the factor per MPG output pulse set in the program is multiplied by to find the
number of input pulses.
Buffer memory address (Axis #1): 1522, 1523