User`s manual
Table Of Contents
- SAFETY PRECAUTIONS
- CONDITIONS OF USE FOR THE PRODUCT
- REVISIONS
- INTRODUCTION
- CONTENTS
- ABOUT MANUALS
- HOW TO USE THIS MANUAL
- ABOUT THE GENERIC TERMS AND ABBREVIATIONS
- PACKING LIST
- 1. OVERVIEW
- 2. SYSTEM CONFIGURATION
- 3. FUNCTION LIST
- 4. INSTALLATION AND UNINSTALLATION
- 5. SCREEN MAKEUP AND BASIC OPERATIONS
- 6. PROJECT CREATION
- 7. SYSTEM CHECKING FROM PERIPHERAL DEVICE
- 8. DATA SETTING
- 9. WRITING TO/READING OF/VERIFICATION OF POSITIONING MODULE DATA
- 10. POSITIONING DEBUGGING
- 11. USEFUL FUNCTIONS
- APPENDIX
- Appendix 1 Read from Module/Write to Module Reference Processing Times
- Appendix 2 Restrictions Depending on Function Version of QD75
- Appendix 3 Functions Added to/Changed from the Previous Versions
- Appendix 4 Uninstalling the License Key FD
- Appendix 5 Parameter Names Shown in GX Configurator-QP Screens and Manuals
- INDEX

8 - 10 8 - 10
MELSOFT
8. DATA SETTING
HELPFUL OPERATION (2)
Perform the following operation when you want to determine the command speed
from the time needed to complete positioning. Use the axis speed calculation
function to calculate the command speed from the travel distance, acceleration
time, deceleration time, time needed for positioning completion and so on.
(Note that the QD75M, QD75MH and LD77 cannot be used.)
1. Open the positioning data edit window of the corresponding axis. (Active status)
2. Click the [Edit]
[Speed of axis setting] menu.
3. Set the Rating, Feedback, Start position, End position, Operation interval and
Data No. in the Axis speed calculation dialog box, and choose ACC interval and
DEC interval.
4. Click the "Calculation" button to show the operation result in the Confirmation
dialog box.
5. Click "OK" in the Confirmation dialog box to change the command speed to that
of the operation result.
[Axis speed calculation dialog box]
[Confirmation dialog box]