Specifications
47 GX Configurator-DP
(c) 2006 MITSUBISHI ELECTRIC CORPORATION
menu by pressing the right mouse button and select 'Insert DP-Slave'. The GSD database dialog
is displayed and the type of the new slave device can be selected. After inserting the slave the
dialog to adjust the
slave parameter settings
is displayed.
The same dialog is displayed, if an existing slave is selected the item 'Modify Settings' is selected
from the context menu.
When selecting the master the following parameters can be edited:
·
Master Settings
·
Bus Parameter
Note:
Any changes in the master configuration, which change the I/O structure (i.e add/remove
slaves or modules), require to generate the Copy- respectively I/O Mapping-POU again
and to repeat the import.
Master Settings
To access the master settings from the graphical network editor:
·
Double-click on the master module or
·
Right-click on the master module to open the context menu and select
Modify Settings
Within the Master Settings network related bus and timing parameters can be set as well as
master specific parameters like the FDL address.
For PROFIBUS modules supporting DP V2, i.e. the QJ71PB92V, the
Master Settings
dialog is
extended by the input of the clock synchronization interval
Watchdog for time sync
. This
parameter is disabled and only displayed in grey for the other PROFIBUS modules: