Specifications

183User Interface
(c) 2013 MITSUBISHI ELECTRIC CORPORATION
Software
Version
Available Functions
GX Developer
8.89
update of CPU parameters in project
no user library
GX IEC Developer
7.04
update of CPU parameters in project
user library generated in sub directory of project, but not
installed in project
GX Works2
< 1.87R
no update of CPU parameters in project
user library generated in sub directory of project, but not
installed in project
>= 1.87R
< 1.501X
no update of CPU parameters in project
user library generated in sub directory and installed in pro-
ject
>= 1.501X
update of CPU parameters in project
user library generated in sub directory and installed in pro-
ject
Note: only with GX Works2 of version 1.87R or newer the project CPU type is checked. In case the
CPU type does not support high speed transfer an error message is displayed.
GX Developer (GD)
GX Configurator-PN cannot generate PLC code for GD, but only update the parameters in a GD pro-
ject. The user is informed, when the parameters have been updated.
GX IEC Developer (GID)
For GID projects GX Configurator-PN cannot install the user library in the project. This must be done
by the user as indicated in the message box.
GX Works2 (GXW2)
The best integration of GX Configurator-PN is with GXW2. For details please see section GX
Works2 Support’.