Specifications

11PROFINET Controller ME1PN1FW-Q
(c) 2013 MITSUBISHI ELECTRIC CORPORATION
1 Device in error
61
Reserved
750
BLOCK 2
Size 2442
vPN_ACYCLIC_RES1
Buffers for acyclic request
answer (2 buffers - max
1500 bytes each incl.
header)
750
vPN_ACYCLIC_RES2
20
vPN_ACYCLIC_DIAG_INPUTS.AD
V_DIAG_*
Advanced diagnostic infor-
mation about issues with
PROFINET
256
Reserved for future time stamping
Not Used. Reserved
2
vPN_ACYCLIC_DIAG_INPUTS.CN
F_CRC
Configuration CRC value.
64
vPN_ACYCLIC_DIAG_INPUTS.IO
D_ADV_STS
Advanced device status
1 : Never Connected
0: Connected
2: Disconnected
3: Connected in error
(IOPS/IOCS/APDU
STATUS in error state)
4: time Out
600
Reserved
1
BLOCK 3
Size 4678
max
vPN_CYCLIC_INPUTS.LIFE_WOR
D_X
PROFINET Controller to
PLC live register
Up to
4677
variable names for cyclic I/O data
are user-defined
Input data received from
each IO-Device. Size up to
9345 bytes.
2.1.1 Management Area
IOC_START_STOP Register
This register is set or cleared by the control CPU to start or stop the PROFINET Controller.
From CPU to PROFINET IO-Controller
Global Var. Identifier
Values
0
1
vPN_MGMT_OUTPUTS.IOC_
START_STOP
IO-controller has to be stopped
If the IO-controller is not star-
ted, nothing is done by
IO-controller has to be started
If the IO-controller is started,
nothing is done by PROFINET