Specifications

This manual confers no industrial property rights or any rights of any other kind,
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be
held responsible for any problems involving industrial property rights which may
occur as a result of using the contents noted in this manual.
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be
the cause of Mitsubishi; machine damage or lost profits caused by faults in the
Mitsubishi products; damage, secondary damage, accident compensation
caused by special factors unpredictable by Mitsubishi; damages to products
other than Mitsubishi products; and to other duties.
For safe use
This product has been manufactured as a general-purpose part for general
industries, and has not been designed or manufactured to be incorporated in
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric
power, aerospace, medicine or passenger movement vehicles, consult with
Mitsubishi Electric.
This product has been manufactured under strict quality control. However,
when installing the product where major accidents or losses could occur if the
product fails, install appropriate backup or failsafe functions in the system.
HEAD OFFICE
HIMEJI WORKS
: MITSUBISHI DENKI BLDG MARUNOUTI TOKYO 100-8310
: 840, CHIYODA CHO, HIMEJI, JAPAN
*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid crystal display panel. It is impossible to completely avoid this symptom, as the liquid crystal display
comprises of a great number of display elements. Flickers may be observed depending on the display color.
Please note that these dots appear due to its characteristic and are not caused by product defect.
*2 The GOT screen saving/backlight off function prevents images from becoming permanently etched on the display screen and increases the backlight life.
*3 ROM in which new data can be written without deleting the written data.
*4 Compliant with IP67 when the USB environmental protection cover is attached. Not compliant when a USB cable is connected. Note that this does not guarantee all
users' operation environment.
3.3 Power Supply Specifications
*1 The GOT continues to operate even upon 5ms or shorter instantaneous power failure.
The GOT stops operating if there is extended power failure or voltage drop, while it automatically resumes operation as soon as the power is restored.
Battery GT11-50BAT lithium battery
Backup target Clock data, alarm history and recipe data
Life Approx. 5 years (Operating ambient temperature of 25°C), Guaranteed: 1 year
Built-in
interface
RS-422
Conforming to serial RS422 standard, 1ch
Transmission speed: 115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape : D-sub 9-pin (Female)
Application : PLC communication
RS-232
Conforming to serial RS232 standard, 1ch
Transmission speed : 115,200/57,600/38,400/19,200/9,600/4,800bps
Connector shape : D-sub 9-pin (Male)
Application : PLC communication, bar code reader connection, PC communication
(Project data upload/download, OS installation, transparent function)
USB
Conforming to serial USB (Full Speed 12Mbps), device, 1ch
Application: PC communication (Project data upload/download, OS installation, transparent function)
CF card
Conforming to PCMCIA, compact flash slot, 1ch
Connector shape : Dedicated for TYPE I
Application : Data transfer, data storage
Option function board For installing option function board, 1ch
Buzzer output Single tone (tone length adjustable)
Environmental protective structure
*4
Equivalent to IP67 (JEM1030) (front section) when the USB environmental protective cover is attached
External dimensions W164(6.46) × H135(5.32) × D56(2.21)[mm](inch)(Excluding USB environmental protective cover)
Panel cutting dimensions W153 (6.03) × H121(4.77)[mm] (inch)
Weight 0.7kg (Excluding mounting fixtures)
Compatible software package GT Designer2 Version2 or later
Item
Specifications
GT1155-QSBD GT1150-QLBD
Input power supply voltage 24VDC (+10% -15%), ripple voltage 200mV or less
Fuse (built-in, not exchangeable) 1.0A
Power consumption 9.84W (410mA/24VDC) or less 9.36W (390mA/24VDC) or less
At backlight off 4.32W (180mA/24VDC) or less
Inrush current 15A or less (26.4V) 2ms
Permissible instantaneous power
failure time
*1
Within 5ms
Noise immunity Noise voltage: 1000Vp-p, Noise width: 1µs (by noise simulator of 30 to 100Hz noise frequency)
Dielectric withstand voltage 500VAC for 1 minute (across power supply terminals and earth)
Insulation resistance 10M or larger by insulation resistance tester (across power supply terminals and earth)
Applicable wire size
0.75 to 2[mm
2
]
Applicable solderless terminal Solderless terminal for M3 screw RAV1.25-3, V2-N3A, FV2-N3A
Applicable tightening torque
(Terminal block terminal screw)
0.5 to 0.8[N
m]
Item
Specifications
GT1155-QSBD GT1150-QLBD
3.4 External Dimensions
4. Installation
4.1 Control Panel Inside Dimensions for Mounting GOT
Mount the GOT onto the control panel while considering the following control panel
inside dimensions.
Applicable cable
Some cables may need to be longer than the specified dimensions when connecting
to the GOT. Therefore, consider the connector dimensions and bending radius of the
cable as well for installation.
4.2 Panel Cutting Dimensions
Make holes in the panel according to the dimensions list below.
Also, ensure 10mm spaces in upper and lower parts of the panel for mounting
fixtures.
164(6.46")
23(0.91")
22
(0.87")
120(4.73")
135(5.32")
47(1.86")
56(2.21")
22
(0.87")
120(4.73")
152(5.99")
120(4.73")10
(0.4")
10(0.4")
Unit: mm (inch)
GRAPHIC OPERATION TERMINAL
GOT
1000
MITSUBISHI
#4-40UNC
(Inch screw type)
M2.6
(Metric screw type)
Panel thickness: 5mm(0.2") or less
53(2.09")
5
4
(0.2")
(0.16")
No Name
1) PLC connection cable/PC connection cable
1)
152(5.99")
120(4.73")
30
(1.19")
140(5.52")
CF CARD
I/F
24V DC
INPUT
+-
Unit: mm (inch)
153
+2
-0
10(0.4") or more
10(0.4") or more
Unit: mm (inch)
121
+2
-0
(6.03" )
+0.08"
-0
(4.77" )
+0.08"
-0
4.3 Mounting Position
When mounting the GOT, the
clearances shown on the right must
be left from a structure or the other
device.
Secure 50mm (1.97") or more on
the left, right and bottom sides of
the GOT to structures or other
devices.
Secure 80mm (3.15") or more on
the top of the GOT from structures
or other devices to allow good
ventilation.
If devices (such as a contactor)
generating radiated noise or those
generating heat are arranged
around the GOT, secure 100mm
(3.94") or more on the back panel.
When using the CF card, secure a sufficient distance on the left side to allow
installation and removal of the CF card.
[Securing 100mm (3.94") or more is recommended.]
4.4 Control Panel Inside Temperature and Mounting Angle
When mounting the main unit to a control panel or similar, set the display section
as shown below.
When the temperature inside the control panel is 40 to 55°C (Horizontal mount),
40 to 50°C (Vertical mount), the mounting angle should be in the range 60° to
105° degrees.
The GOT will be
deteriorated earlier if it is
used at the mounting angle
other than the above.
Therefore, the temperature
inside the control panel
should be within 40°C.
4.5 Installation Procedure
The GOT is designed to be embedded into a panel. Mount the GOT by following
the procedure below. For panel cutting dimensions, refer to Section 4.2. Note that
the panel thickness should be within 5mm.
1) Installing the packing
Install packing to the packing
installation groove on the back panel
of the GOT.
While referring to the cross sectional
view of the packing shown right, push
the thinner side into the packing
groove.
2) Inserting into the panel face
Insert the GOT from the front side of
the panel.
3) Fixing the GOT
Engage the hook of the mounting
fitting (accessory) to the unit fixing
hole of the GOT and tighten the
screw until the GOT is fixed with the
mounting bolt (accessory).
The GOT will be fixed in 4 upper/
lower parts.
Tighten the mounting screw with the
specified torque.
(Failure to do so may distort the
panel and make a surface waviness
on the protective sheet.)
4) A protection film is attached on the display section of GOT prior to shipment.
Remove the film when the installation is completed.
50mm
(1.97")
or
more
80mm (3.15") or more
50mm (1.97") or more
*1 To use the CF card, leave sufficient
distances for removal and installation
of the CF card.
50mm
(1.97")
or
more
*1
GOT
back
panel
GOT
display
section
Control
panel,
etc.
105°
60°
Packing cross
sectional view
Inserting
direction
Packing
Packing
installation groove
Packing
Magnified
illustration
Mounting hole
Mounting
fitting
Mounting
screw
Magnified illustration
5. Wiring
5.1 Power Supply Wiring
Connect the power supply to the power terminals on the back panel of the GOT.
Use 0.75mm
2
or thicker cables to avoid voltage drop and tighten the terminal screw
with the specified torque securely.
Carry out the independent grounding if possible.
If the independent grounding is impossible, carry out the shared grounding as
shown in fig.2) below.
Use the cable of 2mm
2
or more for grounding.
Set the grounding point closer to the GOT to make the grounding cable short as
possible.
1) Recommended terminal shape
6. Maintenance and Inspection
The GOT does not include consumable components that will cause the shorten life.
However, note that battery life is 5 years and LCD life is 50,000 hours. The life of
backlight in GT1155-QSBD is 75,000 hours and that in GT1150-QLBD is 54,000 hours.
It is recommended to replace the battery periodically. (For the replacement of the liquid
crystal screen and backlight, please consult your nearest sales office or FA Center.)
6.1 Daily Inspection
Daily inspection items
Applicable solderless terminal RAV 1.25-3, V2-N3A and FV2-N3A
No. Inspection Item
Inspection
Method
Criterion Action
1 GOT mounting status
Check for
loose mounting
screws.
Securely
mounted
Retighten screws
within the
specified torque
range
2
Connection status
Loose terminal
screws
Retighten
screws with
screwdriver
Not loose
Retighten
terminal screws
Proximate
solderless terminals
Visual check
Proper
intervals
Correct
Loose connectors Visual check Not loose
Retighten
connector fixing
screws
Grounding
(100 or less)
24VDC
power supply
-
+
CF CARD
I/F
24V DC
INPUT
+-
24V DC
INPUT
+-
PC and external
device connection
cables
Power supply terminal
GO GO GO
Other
device
Other
device
Other
device
Grounding
(100 or less)
Grounding
(100 or less)
(1) Independent ground
...... Best condition
(2) Shared grounding
...... Good condition
(3) Common grounding
...... Not allowed
Terminal
screw
Solderless
terminal
Terminal
screw
6.2mm
or less
3.2
3.2
6.2mm
or less
When wiring one cable to
one terminal
When wiring two cables to
one terminal
Solderless
terminal
Refer to the following for the model names of the protection sheet or the replacement
procedure.
GT11 User’s Manual
6.2 Periodic Inspection
Yearly or half-yearly inspection items
The following inspection should also be performed when equipment has been moved
or modified or the wiring changed.
6.3 Battery Replacement
The battery backs up clock data, alarm history and recipe data.
Screen data is stored in the flash memory and data is retained even if the battery is
dead.
Battery model name
GT11 is shipped with the following battery.
Battery replacement procedure
1) Turn the GOT power off.
2) Open the back cover of the GOT.
3) Remove the old battery from the
holder.
4) Disconnect the old battery connector
and insert the new battery connector
within 30s.
(Clock data, alarm history, and recipe
data is retained by the GOT condenser
for 30 seconds.)
5) Insert the new battery into the holder
and close the back cover.
3
Usage status
Dirt on protection
sheet
Visual check
Not
outstanding
Replace with new
one
Foreign material
attachment
Visual check
No foreign
matter sticking
Remove clean
No. Inspection Item
Inspection
Method
Criterion Action
1
Surrounding
environment
Ambient
temperature
Make
measurement
with
thermometer or
hygrometer
Measure
corrosive gas
Display
section
0 to
50°C
For use in control
panel,
temperature
inside control
panel is ambient
temperature
Other
portions
0 to
55°C
Ambient
humidity
10 to 90%RH
Atmosphere
No corrosive
gas
2
Power supply voltage
check
24VDC
Measure
voltage across
terminals.
20.4 to
26.4VDC
Change supply
power
3
Connection
status
Loose
terminal
screws
Retighten
screws with
screwdriver
Not loose
Retighten
terminal screws
Proximate
solderless
terminals
Visual check
Proper
intervals
Correct
Loose
connectors
Visual check Not loose
Retighten
connector fixing
screws
Product name Model name
Battery GT11-50BAT
No. Inspection Item
Inspection
Method
Criterion Action
Back cover
Holder
Connector
Back cover
Holder
Connector
How to confirm production year and month
The production year and month of the battery built in the purchased GOT can
be confirmed by the production No. (serial No.) marked on the GOT main unit.
Battery life
Approximate battery life:
5 years (ambient temperature: 25°C) [Guaranteed for 1 year]
Battery replacement: In 4 to 5 years
Approximate life is 5 years, but life may be shorter depending on the ambient
temperature, therefore, note that the battery must be replaced in 4 to 5 years.
Make sure to purchase a new battery as needed as it self-discharges.
Battery status can be confirmed on a GOT utility screen.
For details of battery status or how to output alarm, refer to the following:
GT11 User’s Manual
GRAPHIC OPERATION TERMINAL
MODEL
IN 20.4
SERIAL
MITSUBISHI ELECTRIC CORPORATION
MADE IN JAPAN
80M1 IND. CONT. EQ
US LISTED
JY550D26101A
540001 BC
26.4VDC
POWER 9.84W MAX
GT1155-QSBD
5 4 0 0 0
Control number
Year (example: 2005)
last digit
1
Month (example: Jun.). 1 to 9: Jan. to Sep.,
X: Oct., Y: Nov., Z: Dec.
CF CARD
I/F
24V DC
INPUT
+-