Specifications

Peripheral Equipment
23
Model Applicable servo amplifier Fig.
SF1252
SF1253
A
B
MR-E-10A/AG to MR-E-100A/AG
MR-E-200A/AG
EMC filter
The following filters are recommended as a filter compliant with the EMC directive for the servo amplifier’s power supply.
External dimensions (Unit: mm) Connections
SF1252
SF1253
LINE
(input side)
LOAD
(output side)
168.0
140.0
156.0
149.5
ø6.0
42.0
8.5
16.0
Model
SF1252
Mass kg (lb)
0.75 (3.1)
Model
SF1253
Mass kg (lb)
1.37 (3.1)
LINE
(input side)
LOAD
(output side)
209.5
168.0
140.0
156.0
8.5
23.0
49.0
ø6.0
A
B
L3
L2
L1
L3’
L2’
L1’
L3
L2
L1
Servo amplifier
LOADLINE
EMC filter
NFB
MC
(Note 2)
(Note 1)
Power supply
3-phase
200 to 230VAC
or
1-phase
230VAC
Notes: 1.
2.
When using a 1-phase 230VAC power supply, connect the
power supply to the L1 and L2 terminals. Do not connect
anything to L3. The 1-phase 230VAC is available only for
MR-E-70A/AG or smaller servo amplifiers.
Connect when the power supply has earth.