Specifications

9
Motor Special Specifications
HF-KE series
Special shaft end specifications
Motors with the following specifications are available.
HF-SE series
With key
(
200, 400, 750W
)
HF-KEMK
Variable dimensions
TS WQKQL U Y
M4 screw
Depth: 15mm
M5 screw
Depth: 20mm
D-cut
(
100W
)
Key way
A-A
W
U
T
Y
øS
A
A
R
Q
QK QL
(Note 1)
(Note 1)
ø8h6
1
RQ
(Unit: mm)
(Unit: mm)
(Unit: mm)
Motor
model
Capacity
(W)
HF-SEMK
Variable dimensions
S WQKQLU Y
24h6
35
55
79
50
75
36
55
5
5
r
4
5
M8 screw
Depth: 20mm
M8 screw
Depth: 20mm
(Note 1, 2)
RQ
Motor
model
Capacity
(kW)
A-A
øS
U
W
Y
A
A
R
Q
QK
r
QL
0.5 to 1.5
2.0
8
0
-0.036
4
10
0
-0.036
+0.2
0
5
+
0.2
0
+
0.01
0
Notes:
1. Cannot be used in applications that involve high frequency. Loose keys may damage the motor shaft.
2. A key is not installed. The key shall be installed by the user.
Motor model
(J)/time
(
J
)
/hour
Times
Brake life (Note 1)
(Braking work per
braking action)
Permissible
braking work
Type
Rated voltage
Brake static
friction torque
Power consumption
(
W
)
at 20°C (68°F)
(
N·m
)
(oz
·
in)
HF-KE series HF-SE series
Spring-action safety brake
24VDC %
13B
45.3
6.3
5.6
20000
(5.6J)
56
0.32
23B
184
7.9
22
20000
(22J)
220
1.3
43B
184
7.9
22
20000
(22J)
220
1.3
73B
340
10
64
20000
(64J)
640
2.4
52B
1200
20
400
20000
(200J)
4000
8.5
102B
20
400
20000
(200J)
4000
8.5
1200
152B
20
400
20000
(200J)
4000
8.5
1200
202B
34
4500
45000
20000
(1000J)
44
6230
Electromagnetic brake specifications
0
-10
0
-10
Spring-action safety brake
24VDC %
Notes:
1. The brake gap cannot be adjusted. The brake life shows the time until the readjustment is needed.
2. The electromagnetic brake is for holding. It cannot be used for braking applications.
200, 400 14h6 30 27 5 20 3 35
750 19h6 40 37 6 25 5 3.56
25
21.5