Specifications

Easy Operation
High Performance
Global Standard
12
Notes:
1. Do not reverse the diode’s direction. Connecting it backwards could cause the servo amplifier to malfunction such that signals are not output, and emergency stop and other safety
circuits are inoperable.
2. Provide a 24VDC ±10% 200mA power supply from an external source for the interface. 200mA is the value when all input/output signals are used. Note that the current capacity can be
stepped down according to the number of input/output points in use. Refer to “MR-E-MA/AG-KH003 INSTRUCTION MANUAL” for details.
3. Always turn on the emergency stop (EMG) signal (normally closed contact) before starting the operation. If not, the operation will not start.
4. Always turn on the forward/reverse stroke end (LSP/LSN) signals (normally closed contact) before starting the operation. If not, the commands will not be accepted.
5. Signals with the same name are connected internally.
6. The malfunction (ALM) signal (normally closed contact) is conducted to SG in normal alarm-free condition.
7. This is for the motor with an electromagnetic brake. The electromagnetic brake terminals (B1, B2) do not have polarity.
8. Connect the shield wire securely to the plate inside the connector (ground plate).
9. This connection is not necessary for QD75D of the positioning unit. Note that the connection between LG and the control common terminal is recommended to increase noise resistance
depending on the positioning unit being used.
10. A shielded multicore cable must be used. The cable length up to 15m is possible in a low noise environment. However, if the RS-232C communication is set up with a baud rate of more
than 38400bps, keep the cable length within 3m.
11. The signals shown apply when using a two-wire type encoder cable. Encoder cable 30m or longer is four-wire type. Refer to “MR-E-MA/AG-KH003 INSTRUCTION MANUAL” for details.
12. When using a power supply, 1-phase 230VAC, connect the power supply to the L1 and L2 terminals. Do not connect anything to L3. The 1-phase 230VAC power supply is available only
for the MR-E-70A-KH003 or smaller servo amplifier.
13. Use the analog monitor/RS-232C branch cable (MR-E3CBL15-P) when connecting the analog monitor output 1 (MO1), analog monitor output 2 (MO2) and a personal computer at the
same time.
14. Connect P and D when using the built-in regenerative resistor.
15. Disconnect P and D when connecting the optional regeneration unit externally.
16. This length applies to the command pulse train input in the differential line driver system. For the open collector system, the length should be 2m or shorter.
Servo amplifier
MR-E-MA-KH003
(Note 11)
B1
B2
SM
Electromagnetic
brake
(Note 7)
RS-232C
TXD
GND
RXD
3
5
2
(Note 10)
15m maximum
Personal computer
running
Microsoft Windows
Maximum +1mA total
Double oscillation (±10V output)
Monitor output
Analog monitor
output 1
Analog monitor
output 2
10k
10k
2m maximum
U
V
W
SM
A
U
V
W
B
C
D
B1
B2
Electromagnetic
brake (Note 7)
(Note 13)
Servo motor
HF-SEM(B)JW1-S100
Servo motor
HF-KEM(B)W1-S100
U
V
W
P
C
L1
L2
L3
U
V
W
D
Encoder
Encoder
1P5
2
LG
3
MR
4
MRR
SD
PLATE
P5
LG
MR
MRR
SD
1P5
2LG
3
MR
4
MRR
SD
PLATE
CN2
(Note 11)
P5E
P5G
MR
MRR
SHD
NFB
MC
Power supply
3-phase 200 to 230VAC
or
1-phase 230VAC (Note 12)
Optional
regeneration unit
(Note 14)
CNP 1 CNP 2
Positioning unit QD75D
PULSE F+
MM15
MM16
MM 9
MM10
MM12
MM14
MM11
MM18
MM13
MM17
Name
Pin No.
PULSE F–
PULSE R–
CLEAR
CLEAR COM
RDY COM
PG0
PG0 COM
READY
PULSE R+
PP
23
PG
22
NP
25
NG
24
CR
5
RD
11
LZ 19
LZR 20
LG 14
LA
15
LAR
16
LB
17
LBR
18
LG
14
OP
21
SD
PLATE
Reset
Forward stroke end
Reverse stroke end
External 24VDC
power supply
(0.2A or more)
(Note 4)
(Note 6)
Malfunction
Zero speed detection
In position
(Note 1)
10m maximum
EMG
SON
RES
LSP
LSN
SG
ZSP
ALM
8
4
3
6
7
13
12
9
INP
10
OPC
VIN
2
1
MO14
A
A
MO2
6
LG
3
SD
RXD1
LG3
SD
PLATE
PLATE
TXD2
CN3
CN2
Shut off when the servo on
signal or the alarm signal
turns off.
EMG
Power supply 24VDC for
the electromagnetic brake
2
3
4
1
1
2
(Note 9) Control common
Encoder A-phase pulse
(differential line driver)
Encoder B-phase pulse
(differential line driver)
Encoder Z-phase pulse
Control common
Control common
CN1
(Note 5)
(Note 16)
10m maximum
10m maximum
2m maximum
(open collector)
R
A
1
R
A
2
R
A
3
(Note 3)
(Note 8)
(Note 8)
(Note 8)
Emergency stop
Servo on
MR-E-A-KH003: Position control operation
Connection example to QD75D (position servo, incremental)
The servo amplifier may be
damaged if the optional
regeneration unit is incorrectly
connected.
(Note 15)
Built-in
regenerative
resistor
(Note 2)
EMG
Shut off when
the servo on
signal or the alarm
signal turns off.
24VDC
Standard Wiring Diagram