Specifications

PRODUCTS
11
DXK-ZMA-S.
Reverse Cycle Inverter.
Manufacturers Speci cations: All spec cation tables are at nominal conditions. Refer to manufacturers technical manuals.
DXK24ZMA-S
DXC24ZMA-S
Indoor DXK24ZMA-S
Outdoor DXC24ZMA-S
Power supply 1 Phase 220~240V 50Hz
Capacity
Cooling T1
kW
7.1 (2.15~8.0)
Heating H1 8.0 (1.6~10.0)
Heating H2 7.70
Input
Cooling T1
kW
2.16 (0.54~2.80)
Heating H1 2.14 (0.37~3.40)
Energy label
Cooling T1
Stars
2
Heating H1 2.5
EER Cooling T1 3.29
COP
Heating H1 3.74
Heating H2 2.49
Sound power level (JIS C9612)
Cooling(Outdoor)
dB(A)
66
Heating(Outdoor) 63
Sound pressure level (JIS C9612)
Cooling(Indoor)
dB(A)
49-45-39-26
Heating(Indoor) 46-43-38-35
Silent mode sound pressure level
Cooling(Outdoor)
dB(A)
45
Heating(Outdoor) 44
Air ow
Cooling(Indoor)
l/s
325-292-233-133
Heating(Indoor) 358-325-258-233
External dimensions (HXWXD)
Indoor
mm
318x1098x248
Outdoor 750x880(+88)x340
Net weight
Indoor
kg
16
Outdoor 57
Refrigerant piping
Liquid line
mm
Ø6.35
Gas line Ø15.88
Connection method Flare connection
Refrigerant R410A
Quantity kg 1.8
Pre charged to pipe
length
m 15
Clean lter Allergen Clear & Photocatalytic Washable Deodorizing Filter
FUNCTIONS
Filter Comfort Air Flow
SUN
Filter
SUN
Filter
SUN
Filter
Allergen
System
Allergen
System
Allergen
System
Self Clean
Operation
Self Clean
Operation
Self Clean
Operation
Allergen
Filter
Allergen
Filter
Allergen
Filter
3
HOT
S
t
a
r
t
K
e
e
p
S
p
u
r
t
Auto
Auto Flap
Air Scroll
Memory
UP/DOWN
Lateral
Swing
Positioning
of
installation
Convenience & Economy Maintenance Others
On Timer
OFF Timer
24h Timer
DRY
Economy
Sleep
MC
Diagnostic
Self
Detachable
Back-up
Switch
Restart
Auto
24h ION
Luminous
Refrigerant Pipe Length
Maximum Pipe Length 30m
Maximum Height Different 20m
DRED enabled model