Specifications

-
241
-
'10 • SR-T-091
Error code
Remote controller:
LED Green Red
Indoor
Keeps flashing
Stays OFF
Content
E47
Active filter voltage error
1. Applicable model
5. Troubleshooting
All models
Diagnosis Countermeasure
YES
YES
NO
Is the power supply normal?
NO
Check
soldered surfaces on the
outdoor PCB for foreign matter
like dust, fouling,
etc.
YES
Is voltage
within the specified range?
NO
Restore normal condition.
Restore normal condition.
Remove foreign matter like
dust, fouling, etc.
Defective outdoor
PCB
ª
Replace.
2. Error detection method
Error is displayed if the
converter voltage exceeds
DC340V (3 times within 20
minutes). Remote controller
may be set after 3 minutes
delay.
3.
Condition of Error displayed
Same as above
4. Presumable cause
Defective outdoor PCB
Dust on outdoor PCB
Anomalous power supply
Note: