Specifications
768
FDC-HKX
Model FDEJ112HKXE2
28
Outdoor
air temp.
(°CDB)
27
29
31
33
35
37
39
Indoor air temperature
17.0°CWB
TC
11.60
11.33
11.07
10.77
10.42
10.15
9.81
SHC
8.72
8.60
8.48
8.35
8.20
8.08
7.93
18.0°CWB
TC
11.94
11.67
11.40
11.13
10.86
10.51
10.21
SHC
8.77
8.66
8.54
8.42
8.31
8.16
8.04
19.0°CWB
TC
12.25
12.01
11.74
11.47
11.20
10.93
10.60
SHC
8.80
8.70
8.59
8.48
8.37
8.26
8.12
20.0°CWB
TC
12.50
12.30
12.07
11.80
11.54
11.27
11.00
SHC
8.80
8.72
8.63
8.52
8.42
8.31
8.20
21.0°CWB
TC
12.84
12.57
12.34
12.14
11.87
11.60
11.33
SHC
8.83
8.72
8.64
8.56
8.46
8.36
8.26
22.0°CWB
TC
13.15
12.90
12.63
12.39
12.21
11.94
11.67
SHC
8.84
8.75
8.65
8.56
8.49
8.39
8.30
Air flow
(m
3
/min)
Model FDEJ140HKXE2
34
Outdoor
air temp.
(°CDB)
27
29
31
33
35
37
39
Indoor air temperature
17.0°CWB
TC
14.50
14.17
13.83
13.47
13.02
12.68
12.26
SHC
10.78
10.63
10.48
10.31
10.12
9.97
9.78
18.0°CWB
TC
14.92
14.59
14.25
13.92
13.58
13.13
12.77
SHC
10.84
10.69
10.55
10.40
10.26
10.07
9.91
19.0°CWB
TC
15.32
15.01
14.67
14.34
14.00
13.66
13.24
SHC
10.88
10.75
10.60
10.46
10.32
10.19
10.01
20.0°CWB
TC
15.62
15.37
15.09
14.76
14.42
14.08
13.75
SHC
10.87
10.77
10.65
10.52
10.38
10.25
10.12
21.0°CWB
TC
16.04
15.71
15.43
15.18
14.84
14.50
14.17
SHC
10.90
10.77
10.66
10.56
10.43
10.30
10.18
22.0°CWB
TC
16.44
16.13
15.79
15.48
15.26
14.92
14.59
SHC
10.91
10.80
10.67
10.56
10.47
10.35
10.23
Air flow
(m
3
/min)
(g) FDFL Series
Model FDFLJ28HKXE2
12
Outdoor
air temp.
(°CDB)
27
29
31
33
35
37
39
Indoor air temperature
17.0°CWB
TC
2.90
2.83
2.77
2.69
2.60
2.54
2.45
SHC
2.58
2.55
2.52
2.49
2.46
2.43
2.40
18.0°CWB
TC
2.98
2.92
2.85
2.78
2.72
2.63
2.55
SHC
2.60
2.57
2.55
2.52
2.49
2.46
2.43
19.0°CWB
TC
3.06
3.00
2.93
2.87
2.80
2.73
2.65
SHC
2.62
2.59
2.57
2.54
2.52
2.49
2.46
20.0°CWB
TC
3.12
3.07
3.02
2.95
2.88
2.82
2.75
SHC
2.63
2.61
2.59
2.56
2.54
2.52
2.49
21.0°CWB
TC
3.21
3.14
3.09
3.04
2.97
2.90
2.83
SHC
2.64
2.62
2.60
2.58
2.56
2.54
2.51
22.0°CWB
TC
3.29
3.23
3.16
3.10
3.05
2.98
2.92
SHC
2.66
2.64
2.61
2.59
2.58
2.55
2.53
Air flow
(m
3
/min)
Model FDFLJ45HKXE2
14
Outdoor
air temp.
(°CDB)
27
29
31
33
35
37
39
Indoor air temperature
17.0°CWB
TC
4.66
4.55
4.45
4.33
4.19
4.08
3.94
SHC
3.86
3.82
3.77
3.72
3.66
3.62
3.56
18.0°CWB
TC
4.80
4.69
4.58
4.47
4.37
4.22
4.10
SHC
3.89
3.85
3.80
3.76
3.71
3.66
3.61
19.0°CWB
TC
4.92
4.82
4.72
4.61
4.50
4.39
4.26
SHC
3.91
3.87
3.83
3.79
3.75
3.70
3.65
20.0°CWB
TC
5.02
4.94
4.85
4.74
4.64
4.53
4.42
SHC
3.92
3.89
3.85
3.81
3.77
3.73
3.69
21.0°CWB
TC
5.16
5.05
4.96
4.88
4.77
4.66
4.55
SHC
3.94
3.90
3.87
3.84
3.80
3.76
3.72
22.0°CWB
TC
5.28
5.18
5.08
4.98
4.91
4.80
4.69
SHC
3.95
3.92
3.88
3.85
3.82
3.78
3.75
Air flow
(m
3
/min)
Note (1) Symbols are as follows :
TC : Total cooling capacity (kW)
SHC : Sensible heat capacity (kW)