Specifications

918
OPTION
OPTION
19.5 RECEIVER AMP KIT (RCND-KIT-HE)
This is a controller that makes it possible to use a wireless remote controller for the heat pump wired remote control unit (single
package 8-type series, multi-KX2 series).
(1) Receiver appearance and operation
CHECK MODE
ON/
OFF
CHECK
FILTER
CHECK
TIMER RUN/
CHECK
REMOTE CONTROLLER SIGNAL RECEIVING SECTION
CHECK MODE INDICATOR
When a malfunction occurs, the indicator indicates the status of malfunction by symbol.
BACK UP SWITCH
CHECK SWITCH
This switch is used for maintenance service.
RUN/CHECK LAMP
The lamp flashing are indicated in 3 patterns as follows.
Light up in green: During operation
Flashing in green: “HOT KEEP” (during heating mode)
Flashing in red: Anirregularity occurs in the air conditioner.
TIMER LAMP (GREEN)
This lamp is lit during the timer operation.
FILTER CHECK LAMP (RED)
When this lamp is lit. clean the filter.
These lamps flashing when the
signal is received from the remote
controller.
When the remote controller is missing or defective, this switch can start
and stop the air conditioner.
Use the buck up switch when the battery is exhausted, or when the
remote controller is missing or directive.
Usually operate the remote controller.
When the signal is received from the remote controller, these indicating lamps flashing twice in turn
as follows.
TIMER RUN/CHECK
(Green) (Green)
(2) Installation
(a) Accessories (Confirm the following accessories).
1
2
3
1
2
1
Remote controller
holder
Screw for holder
Dry cell for remote
controller
1
2
3
4
2
1
5
5
Screw for light
detection adaptor
Fixing band
Clamp
Screw for clamp
1
2
3
1
2
2
Light detection section
installation bracket
Screw for the
bracket
Installation fitting
1
2
3
4
5
6
7
Light detection
adaptor
Wireless remote
controller
Parts set (A)
Parts set (B)
Parts set (C)
Instruction manual
1
1
1
1
1
1
1
Wiring (3m)