Specifications
907
OPTION
Item
Name
Center Console SLA-1-E Center Console SLA-2A-E
Registration monitoring —— Displays the air-conditioner Nos. 0 to 47.
Operation monitoring
LED display of the operational state of each unit LCD display of the operational state of each unit
Error monitoring Red LED lights up for each unit
Operation mode monitoring ——
Room temperature monitoring ——
Operation status monitoring ——
Filter sign monitoring —— LED flashing display of filter sign
Priority setting monitoring ——
Group settings —— Individual, group, simultaneous
Group registration —— Max. of 16 groups (voluntary setting)
Priority settings ——
REMOTE, CENTER, CENTER & REMOTE
Function change —— Auto swing ON/OFF
Operation mode settings —— COOL, HEAT, FAN, DRY, AUTO
Air flow settings —— HI, MED, LO
Timer settings External operation input enabled/disabled
Room temperature settings —— 1°C intervals from 18 to 30°C
Notes (1) When using SLA-1-E a standard remote controller is required.
(2) The maximum number of SLA-1-E units that can be used in 1 network is 6, and the maximum number of SLA-2A-E that
can be used in 1 network is 3, but the number of units that can actually be used differs depending on the following
configurations, so do not exceed these limitations.
Number of SLA-1-E Number of SLA-2A-E
03
12
22
31
40
50
60
LCD display of error code and inspection
LED lights up for each unit
LCD display of COOL, HEAT, FAN,
DRY, and AUTO
LCD Display of air-conditioner return air
temperature for each unit 13, 13~35, 35
Flashing LCD display of unmatched
unit’s operation mode
LCD display of REMOTE, CENTER,
and CENTER & REMOTE
Monitoring
Settings