Specifications

FDC-HKXR
955
Item
W
W
W
CMM
kg 22
Hi: 14 Me: 12 Lo: 10
dB(A)
mm
Internal thermostat for fan motor.
Frost protection thermostat
Models
FDEJ36HKXE2B
(3)
3600
FDEJ45HKXE2B
(3)
4500
4000
1 Phase 220/240V 50Hz
Electronic Expansion Valve + Capillary tube
Line starting
Not possible
Polypropylene net 2(Washable)
Rubber sleeve(for fan motor)
Polyurethane foam
Flare piping
Connectable with VP20
Necessary (both Liquid & Gas lines)
Mounting kit
_
FDCP2001HKXRE2, 2501HKXRE2
Thermostat by electronics
Centrifugal fan 2
Liquid line: 6.35(1/4"), Gas line: 12.7(1/2")
mm(in)
Remote control switch (Optional:RCD-HKX-S-E2)
Hi: 43 Me:40 Lo: 38
Louver fins & inner grooved tubing
5000
40 1
(f) Ceiling suspension type (FDE)
Models FDEJ36HKXE2B, 45HKXE2B
184 1000 650
Nominal cooling capacity*
1
Nominal heating capacity*
2
Power source
Net weight
Starting method
Fresh air intake
Air filter, Q'ty
Shock & vibration absorber
Insulation (noise & heat)
Room temperature control
Connecting method
Drain hose
Insulation for piping
Accessories
Optional parts
Outdoor units to be combined
Motor
Air flow(Standard)
Exterior dimensions
Height Width Depth
Refrigerant equipment
Heat exchanger
Operation control
Operation switch
Installation data
Refrigerant piping size
Noise level
Safety equipment
Refrigerant control
Air handling equipment
Fan type & Q'ty
Item
Indoor air temperature Outdoor air temperature
Standards
ISO-T1,JIS B8616
Operation
DB WB DB WB
Cooling*
1
27
Heating*
2
20
19 35
7
24
6
(1) The data are measured at the following conditions.Notes
(2) This packaged air-conditioner is manufactured and tested in conformity with the following standard.
JIS B8616"UNITARY AIR-CONDITIONERS"
(3) The number "2", following the type of each model, represents"CE-marked model" especially for European Union, and for European nations which
require CE marking.