Operation Manual

25
Control
1.0 [N] Hot water temp.
Menu 1.1 [N] Max HW/Period time
The time of the hot water period and the time for the whole
period are shown here. Whole period is shown in brackets.
Shown for both hot water charging and heating when
necessary:
Time for Heating (Max.) when heating is in progress.
Time for Hot water (Max.) if hot water charging is in progress.
Menu 1.2 [N] Start temperature HW
The temperature when the heat pump starts hot water charging
is set here.
Setting range: 25 – 55 °C
Menu 1.3 [N] Stop temperature HW
The temperature when the heat pump stops hot water charging
is set here.
Setting range: 30 – 60 °C
Menu 1.4 [U] Stop temperature XHW
The desired temperature during extra hot water is set here.
Setting range: 40 – 65 °C
Menu 1.5 [U] Heat pump stop XHW
The desired stop temperature during extra hot water for the
heat pump is set here.
Setting range: 40 – 60 °C
Menu 1.6 [U] Max heat p. time XHW
Here you select the maximum amount of time the heat pump
can charge hot water for during extra hot water.
Setting range: 0 – 60 min
Menu 1.7 [U] Interval XHW
Periodic time based extra hot water is selected here.
Extra hot water is shut off at the value “Off”. Extra hot water
is started when the value is conrmed.
Setting range: 0 – 90 days
Menu 1.8 [U] Next XHW action
Time to the next periodic Extra hot water operation is shown
here.
Menu 1.9 [U] HW run time
Shows how long hot water charging with the compressor has
been in progress (accumulated).
Menu 1.12 [N] Return
Return to menu 1.0.