Operation Manual
14
MT500
*These graphs are based on the following conditions :
Inlet water temperature : 15°C
Outlet water temperature : 40°C
Outdoor air temperature : 7°C
Hot water Supply is unlimited in case 8
ℓ
/min at the condition as
the capacity is bigger than hot water supply.
Prioritizing
When the water temperature in the tank drops, heat pump
operation shifts to hot water production. In case there is
demand for both hot water and heating/cooling for long time,
operation mode is periodically switched between hot water and
heating/cooling. For details, see menu 1.0 Hot water temp and
8.5.0 Period settings.
Comfort setting hot water
The integrated water heater is a coil model and is heated by
circulating water, which is heated by the heat pump.
During “normal” consumption it is enough to run the heat
pump to supply the different tapping points of the house with
hot water. The temperature of the hot water in the water heater
then varies between the set values.
Under section 1.0 [N] Hot water temp. on page 25 there is a
complete description of menu settings for hot water
temperatures.
Available volume
<HMA100V, HMA100VM>
<HMS140VA, HMS140V>
MT300
0
200
400
600
800
1000
1200
1400
1600
48 50 52 54 56 58 60 62 64
Stop temp. HW(°C)
Supply water volume (
ℓ
)
Hot water volume
10 ℓ /min
12 ℓ /min
14 ℓ
/min
16 ℓ
/min
24 ℓ
/min
8ℓ/min
12ℓ/min
16ℓ/min
0
100
200
300
400
500
600
50 53 56 59 62 65
Stop temp. HW (°C )
Supply water volume (
ℓ
)
Hot water volume
0
50
100
150
200
250
300
350
400
450
50 53 56 59 62 65
12 ℓ /min
16 ℓ /min
Stop temp HW (°C)
Supply water volume (
ℓ
)
Hot water volume
Comfort setting hot water