User`s manual
Observing the display of the auto swing, press the
“AUTO SWING” switch when a desired position is
displayed.
The display of the auto swing will stop at the position,
and then the swing flap will stop swinging and be fixed.
Though the display of the auto swing
stops immediately after the switch is
pressed, the swing flap will stop later.
This is not a malfunction.
Press the “timer” switch.
Set to “PROGRAM”.
Set “OFF” of the timer.
Set the timer in the order of 1 and 2 shown in above “ON/
OFF TIMER SETTING”.
Set “ON” of the timer.
Set the timer in the order of 1 and 2 shown in above “ON/
OFF TIMER SETTING”.
Press the timer switch.
The display changes with the following sequence:
Set to [OFF] or [ON].
Set the timer time.
Set the time to stop or start the operation with the same
manner as procedure 2 to 6 on page 5.
ADJUSTMENT OF AIR FLOW
This display changes
continuously.
Horizontal adjustment
(FDTS, FDE, FDK Series)
Vertical louver (manually operated)
provided behind the swing louver.
Swing flap
The swing flap swings vertically by the “AUTO SWING” switch. It
can be adjusted also manually and fixed at any desired position.
Swing flap
The swing flap swings vertically by the “AUTO SWING” switch.
NOTICE (1) Following adjustment is not effective where the
panel is not equipped with the auto swing mecha-
nism. It is adjusted manually instead.
Swing flap
The swing flap swings vertically
by the “AUTO SWING” switch.
Vertical louver (manually
operated)
FDT Series FDTW Series
FDE Series
Note:
• A panel which does not have
“AUTO SWING” functon can
not be adjusted by the pro-
cedure shown below.
• To minimize dust accumula-
tion caused by the blow's di-
rection, set the flap direction
to a lower position.
FDK Series
Swing flap
The swing flap swings vertically
by the “AUTO SWING” switch.
FDTS Series
Setting position is
indicated.
Blow-out position
recommendation
(When fixed)
When fixing the swing
louver in this position, it is
necessary to turn the verti-
cal louver to right and left.
(FDTS, FDE,
FDK Series)
COOL
DRY
HEAT
Vertical louver (manually operated)
■ “OFF” timer: stops operating the air conditioner when a set time has elapsed.
“ON” timer: starts operating the air conditioner when a set time has elapsed.
1
2
● The operation is stopped or started at the setting time and the indication
on the timer changes to “No indication”.
Time change
Reset the desired time using the time setting switch and the setting
switch.
The time that has been set before becomes invalid and the timer opera-
tion is restarted with the reset time as the starting point.
Release
When it is desired to change to the normal operation during the
operation of timer, press the timer switch to indicate no-indication
or time indication.
The timer becomes invalid and the mode changes to the normal operation.
CHECK
FAN
SPEED
AUTO
SWING
TIMER
SET
MODE
TEMP
TIME
TIMER
OFF
PM
SE T TEMP
°C
FAN
HI
°C
REMOTE
COOL
FILTER
RESET
I
1
No indication Time indication Timer ON
Program timer Timer OFF
The air conditioner
turns on or off when a
set time has elapsed.
ON / OFF TIMER SETTING PROCEDURE
3
● The program timer operation starts.
1
2
● The program timer operates the shorter set time first.
● If “ON” and “OFF” are set at the same time, the “OFF” timer will
operate at the set time everyday.
This will work as a prevention when it is forgotten to turn off.
Timer operation indication
● Timer indication
The set timer mode “PROGRAM” and the timer mode “OFF” or “ON” that
operates next will be displayed.
■ Timer operation of two actions on a day is possible by combination of OFF timer and ON timer of PROGRAM timer.
Once after the PROGRAM timer is set, the air conditioner will be started and stopped at the same time everyday.
PROGRAM TIMER SETTING PROCEDURE
The program timer
starts and stops the
air conditioner at the
same time everyday.
CHECK
FAN
SPEED
AUTO
SWING
TIMER
SET
MODE
TEMP
TIME
PROGRAMTIMER
OFF
PM
SE T TEMP
O
C
HI
FAN
O
C
REMOTE
COOL
FILTER
RESET
I
3
●
The unit can be turned on or off by ON/OFF switch even if the timer is used.
● When the control changes to [Center] by setting of the option control-
ler, the operation by timer becomes invalid.
NOTE
NOTE
● Change of setting time and how to release the setting.
Refer to the above item ON/OFF TIMER SETTING PROCEDURE.
Vertical adjustment
To swing the flap
Press the “ON / OFF” switch, and press the “AUTO
SWING” switch.
The swing flap swings vertically in continuation with
the display changing.
The movement of the swing flap is not
identical to the movement displayed.
To fix the flap in a desired position
NOTE
NOTE
Operation of swing flap during the heating preparation cycle
When the message “HOT KEEP” is shown on
the display, the swing flap adjusts automatically
in the horizontal position.
When the heating preparation is over and the
normal operation starts, the swing flap returns
to the setting position.
Request: Do not move the flap forcibly by hand, it will be sometimes bro-
ken by doing so.
Holizontal
position
Adjust the vertical louver to a
desired position by moving the
louver with hand.
6
PSA012B656_E_A3 06.7.28, 6:02 PM6