Specifications
Correspondence to Individual or Centralized Start/Stop up
to the Maximum of 16 Units
Center Console
SLA-2A-E
Maximum of 48Package Air-conditioner Units
(
1to16 Groups
)
can be
Centrally Controlled.
Useful thin and compact design
OSixteen operation switches are used to provide the
batch control of 16 groups at the maximum (Number of
object is 48 units), which improved the operability
sharply.
OA large, easy-to-see LED display is adopted. The
operation condition and contents of setting can be
confirmed easily.
OThe center console can be connected at anywhere on
the Super Link Network.
Individual control by New Standard Remote
Control is possible as well.
OIn addition to the individual and centralized control,
the individual control from the New Standard Remote
Control is possible by setting to the center & remote.
OThe New Standard Remote Control can be
eliminated.
The SLA-1 makes ON/OFF control possible with
each floor as a unit.
OIn the case that the center console SLA-2A-E is set to
the individual or each floor, connecting the SLA-1-
Emakes the ON/OFF control of individual/each floor
possible from the SLA-1-E.
Expansion of network control
OFree connection is possible from 1 to 48 units per
Center Console
SLA-1-E
A new type that a weekly timer can be connected without an interface. The remote control "prohibit/allow"
function is newly equipped on the SLA-2A-E.
one group and up to the maximum of 16 groups (The
total number of units of the whole group is 48.) even
though the addresses are not consecutive.
OUp to the maximum of 3 unit of SLA-2A-E can be
connected in the same Super Link Network.
OThe Super Link can stop/start and monitor the package
air-conditioner individually, in batch or by the group, it
also can control the operation mode and temperature
setting. Thus, the Super Link creates advanced air-
conditioning control system.
Demand control and emergency stop control
ODemand control by the external signal is possible.
OEmergency stop control is possible as well.
Considerate power outage compensation
OThe power outage compensation function is provided
as the standard features.
In the event that there is a power outage during
operation, the operation is restarted after restoration
using the information stored in the memory.
Correspondence to program operation
OBy connecting a separately sold weekly timer, the
program operation per group up to 16 groups can be
performed.
The wiring installation work is simplified by
virtue of the simple system
OThe non-polar two-wire type simple system greatly
reduces the wiring installation work.
Connection with the weekly timer without
interface
OAn interface, which has been necessary until now,
became unnecessary.
The weekly timer can be connected easily. The SLA-2A-
E alone is equipped with the equivalent function with the
old SLA-2-E.
Kind Combination Remarks
Standard Remote Control
Commercial timer
Weekly timer(SCA-WT-E)
SLA-2A-E
OK
OK
OK
Required
Batch controlled ON/OFF only
See below mentioned description on SLA-2A-E.
Combination
Kind Combination Remarks
New Standard Remote Control
SLA-1-E
SLA-2A-E
Weekly timer(SCA-WT-E)
Commercial timer
External input
OK
OK
OK
OK
OK
Individual
or
plural connections
Emergency stop by input from the non-voltage "a" contact,
demand control, and allowed/ prohibited
Possible without connection
Combination with SLA-2A-E
SLA-1-E
Case 1
Case 2
Case 3
Case 4
6 units
0
3 units
2 units
0
3 units
1 unit
1 unit
SLA-2A-E
Combination of SLA-1-E and SLA-2A-E
13
This center console provides the operation,
stop, and inspection for the package air-
conditioners up to the maximum of 16 units.
OSixteen operation switches are used to control the
package air-conditioners up to the maximum of sixteen
(16) units, which improved the operability sharply.
Operating condition confirmation function per
individual standard unit
OThe sixteen (16) LEDs display the Nos. of units
being operated. They light green during operation, red
during inspection (error), and light-off at stop or non-
connection to indicate the condition of each unit at a
glance.
Correspondence to each floor installation
OSLA-1-Es up to the maximum of six units can be
connected on the same network of the Super Link.
OIn the case of consecutive addresses, any number
from 1 to 16 units can be set per one [SLA-1-E].
Considerate design for power outage
compensation
OThe compensation function for the power outage is
equipped as the standard features. In the event that there
is a power outage during operation, the operation is
restarted after restoration using the information stored
in the memory.
Thin and compact design that does not occupy
much space
OA compact design of H: 120 mm (4.72 in.) x W:120
mm (4.72 in.), and 15 mm (0.6 in.) thick .
The wiring installation work is simplified by
virtue of the Simple System.
OTying-in the center console to the Super Link
Network can be accomplished directly by only
connecting the signal wire of non-polar two-wire type,
which simplifies the wiring installation work.