oA thermostat function, which can be switched between the
air conditioner return air sensor and remote controller
built-in sensor is provided.
oA power failure compensation function is provided as
standard function. If a power failure occurs during
operation, and then is recovered, operation is restarted
according to the settings before the power failure
occurrence.
(However, it is necessary to set the timer auto swing again.)
One indoor unit can connect two remote controller each.
Remote-controller :Model name
FDR and FDUM series are not provided with AUTO
SWING switch = RCD-HKX-E2
FDFL series are also not provided with AUTO SWING
switch = RCD-HKXFL-E2
Except above indoor = RCD-HKX-S-E2 (with Auto swing
switch)
oThe timer is indicated by the
12-hour system, AM or PM.
Additionally, it is also possible
to set the time in minutes.
oThe same key is used for timer setting and room
temperature setting. As the number of indication keys
with rotary selection was reduced, the display screen was
enlarged, improving operability. Additionally, touch
feeling of operation keys is much improved.
o2 remote controllers can be connected to one indoor
unit (or one indoor unit group).
Cover opener
A handle is provided on the cover, resulting in
improvement of open/close operability.
Receiver amp Kit (RCND-KIT-HE)
By mounting the receiver amp kit (option) ,wireless use
is possible with all series.
oBoth the standard remote controller and wireless
remote controller can be installed simultaneously for one
indoor unit.
oThe wireless remote
controller is enclosed.
Use of a clear LCD panel allows easy recognition of operating states.
The remote and timer operation indications are displayed even while
the air conditioner is being stopped.
New
Standard remote controller
(optional item)
Filter sign
Indicated when cleaning of the air filter is needed.
Check switch
Used during service work.
Heating ready indication
Indicated when the cooling air blow is prevented.
Operation mode indication
Used to indicate a selected operation mode.
Remote indication
Indicated while the air conditioner is being
controlled using theindividual remote controller.
(This indication is also displayed even while the air
conditioner is being stopped.)
Auto swing switch
Used to start and stop the swing louver.
Mode switch
Used to select a desired mode.
Temperature set/ Time set
Used to set the room temperature and timer time.
Operation / Check lamp
This lamp is lit in green during operation
and flashes in red if an error occurs.
Intake air temperature indication
Indicates the intake air temperature.
Run /Stop switch
Operation is possible even though
the cover is not opened.
Center indication
Indicated while the air conditioner is being
controlled using the optional center console.
Timer indication
Indicates the contents of timer operation.
(Contents of timer operation are displayed even while
the air conditioner is being stopped.)
Set temperature indication
Indicates the set temperature during normal operation.
Air volume indication
Indicates the set air volume.
Timer switch
Used to select the contents of timer operation.
Remote controller built-in sensor
Set switch
Used to set the timer time.
Auto swing indication
Indicates the swing louver status.
Air volume switch
Used to set an air volume.
Functionality
Operability