User`s manual
FDR Series
1. Push up the center portion 1 of the suction panel.
2. Pulling towards you, swing down the panel.
3. Remove the corrugated filter from the hook by
turning the hook.
4. Slide the flat filter towards center and remove it.
Note (1) Only one corrugated filter is used for
FDR208-308 models.
1
2
Pin (B)
1
2
Pin (A)
Outer frame
of panel
Inner frame
of panel
FDT Series
1. Take hold of the notches to the left and right and
slowly pull the grille downwards.
2. Hold the hooks as illustrated below (left and right)
at lower end of filter and pull while gently pushing
upwards.
FDFL Series
Cleaning the Air Filter
Clean the air filter periodically at the end of cooling and heating seasons.
Removal
CAUTION
●
Do not open the inlet grille until fan stops completely.
●
Fan will continue rotating for a while by the law of inertia after opertion is being stopped.
Thinner
Petrol
Tooth powder
Do not
use!
MAINTENANCE
Points to observe
Turn off the power switch. Do not touch the equipment with wet
hands.
Do not use hot water or volatile liquids.
Cleaning
1. Clean the air filter by tapping it or with a vacumm cleaner. It is better to clean it
with water.
If the air filter is very dirty, dissolve some neutral detergent in the lukewarm water
(approx. 30°C), rinse the filter, and wash out the detergent thoroughly in clear
water.
2. After drying the air filter, set it up on the air conditioner, and press the FILTER
RESET switch.
CAUTION
●
Do not dry the air filter with fire.
●
Do not run the air conditioner without the air filter.
4 Flat filter
Hook
3 Corrugated filter
PULL
Filter
Hook
1. Slide the suction grill lever toward the arrow direction
(
) and open this side.
2. Pull out the air filter toward the up side.
Air filter
7
The unit does not work at all
Has the power switch been turned on? Do you have a normal municipal
electricity supply?
Is your earthed plug alright?
If not, this may be dangerous. Turn off the
power supply immediately and contact your
dealer.
Have you set the thermostat at a
suitable temperature?
Is the air filter clean?
Did you leave any doors or windows
open?
Is swing flap in the horizontal posi-
tion? (During heating operation)
Air blow will not reach the floor if the swing flap
is set horizontally.
Are there any obstacles blocking the
air inlet or outlet?
Is there a heat source in the room? Are there too many people in the room?
Please carry out the following checks before making a service call.
The switch
is not ON.
Power
failure?
Cooling air is coming out. (on heating operation)
Isn’t the air conditioner under prepara-
tion of heating operation?
Page 9
Is there any direct sunlight entering the room?
When the air conditioner does not operate properly after you have checked
the above mentioned items or when the following phenomenon is observed,
stop the operation of the air conditioner and contact your sales dealer.
●
The fuse or breaker often shuts down.
●
Water drops off during cooling/dehumidfying operation.
●
There is an irregularity in operation or abnormal sound is audible.
●
Inspection lamp blinks.
TROUBLESHOOTING
At the end of the season
●
Operate the unit for half a day in FAN mode in fair weather to dry the inside properly.
●
Stop the unit and turn off the power switch.Even when the air conditioner has been stopped, it still uses electricity.
●
Clean the air filter and re-install it.
Care and Cleaning of the unit
●
Clean with soft and dry cloth.
●
If it is very dirty, dissolve a neutral detergent in lukewarm water and use this for dampening the cloth.
When you have finished wiping, remove the detergent with clean water.
At the beginning of the season
●
Remove any objects that may obstruct the air inlet and outlet of both the indoor and outdoor units.
●
Ensure that the air filter is clean.
●
Switch on the power switch 12 hours before you start operating.
Poor cooling or heating
Poor cooling
Hot keep
operation