User`s manual

Observing the display of the auto swing, press the AUTO SWING switch when
a desired position is displayed.
The display of the auto swing will stop at the position, and then the swing flap will stop
swinging and be fixed.
Though the display of the auto swing stops immediately after the switch
is pressed, the swing flap will stop later.
This is not a malfunction.
ADJUSTMENT OF AIR FLOW
This display changes
continuously.
Setting position is
indicated.
Blow-out position
recommendation
(When fixed)
Vertical adjustment
To swing the flap
Press the ON / OFF switch, and press the AUTO SWING switch.
The swing flap swings vertically in continuation with the display changing.
The movement of the swing flap is not identical to the movement
displayed.
To fix the flap in a desired position
NOTE
NOTE
Operation of swing flap during the heating preparation cycle
When the message HOT KEEP is shown on the display, the swing flap adjusts
automatically in the horizontal position.
When the heating preparation is over and the normal operation starts, the swing
flap returns to the setting position.
Request: Do not move the flap forcibly by hand, it will be sometimes broken by doing so.
6
FDT Series
AUTO
COOL
DRY
HEAT
Swing flap
The swing flap swings vertically by the AUTO SWING switch.
NOTICE (1) Following adjustment is not effective where the
panel is not equipped with the auto swing mecha-
nism. It is adjusted manually instead.
Holizontal
position
Set a suitable room temperature.
Excessive cooling is not healthy, and wastes electricity.
Clean the air filter periodically.
If air filter is clogged:
The cooling effect is reduced, which
results in excessive use of electricity.
It may cause malfunctioning.
Water may drip when in cooling
mode operation.
Avoid direct sunlight and draughts.
Cut out direct sunlight by drawing the curtains
or blinds when cooling. Keep windows and
doors shut, except when ventilating.
Adjust the air flow direction properly.
Avoid facing the cool air for any length of time.
Furthermore, take care not to aim the airflow di-
rectly at small animals or plants.
Use the circulator if you feel coolness
around your feet during the heating
operation.
If you feel cold around your feet because of the height
of the ceiling, we recommend you use a circulator.
For details please consult your dealer.
Beyond the recommended range, the equipment may malfunction and/or damage may be caused to property.
COMFORTABLE USE
When cooling or heating season
is over, clean the air filter.
Adjust the temperature and humidity within the following ranges.
Suitable
temperature
1. Open the covers provided at both sides of the blow air exit
on the indoor unit.
Refrain from pressing the cover backward too strongly.
Cover may be broken.
2. Turn the louver knobs to the Upward or Forward posi-
tion.
Turning it to the Upward position directs the air blow upward or,
if it is turned to Forward position, the air blow is directed
forward.
The louver knob is provided at each side so that it can be set at
the Upward or Forward position separately from the other.
3. Install the cover as it was.
FDFL Series
Cover
Louver knob
Blow air exit
(Louver is provided inside.)
Louver knob
Upward
blow
Upward
blow
Forward
blow
Forward
blow
Louver knob
To turn the wind direction in the upward or forward direction, turn by hands the
louver knobs provided at both sides at the blow air exit on the indoor unit.
NOTE
Indoor temperature Outdoor temperature Indoor humidity
Classification
Approx. 21 to 32°C
(Type 6, Type 208, 258)
Approx. 18 to 32°C
(Type 308, 408, 508, 808, 1008)
If you use the air conditioner at 21°C
or less for a long time, the unit may
frost up and cooling/dehumidifying
operations may become impossible.
Approx. 80% and less
If the air conditioner is operated in
very humid surroundings for a long
time, the unit's surface may get
damp and some water may drip, or
some watery mist may escape from
the air outlet.
Approx. 10 to 43°C
(Type 6 HEN model, Type 208, 258 HEN3,
CEN, CEP models)
Approx. -5 to 43°C
(Type 208, 258 HEN3A, Type 308, 408, 508, 808, 1008)
Approx. 10 to 54°C
(Type 6 HES model, Type 6 model for cooling only)
Cooling and
dehumidifying
operation
Heating
operation
Approx. 27°C and less Approx. -10 to 21°C
(Type 6, Type 208, 258)
Approx. -10 to 24°C
(Type 308, 408, 508, 808, 1008)
When the outdoor temperature goes down, the heating
capacity decreases.
Condition