User`s manual

CONTROLS AND FUNCTION
The illustration below shows the status that the cover is open. The liquid crystal display area indicates the full
contents of display for explanation.
Pull the knob towards you to open the cover downward.
CAUTION
AUTO SWING switch are not equipped for FDR, FDU, FDUM, FDFL series.
Operation mode display
The selected operation mode is
indicated.
Operation/check indication lamp
During normal operation: Green
lamp is lit.
When an error occurred: Red lamp
flickers.
ON/OFF switch
This switch performs run/stop of the
air-conditioner. Press switch once to
run and press it again to stop.
(The switch can be operated without
opening the cover.)
The indicated temperature value
may be different from the indication
of thermometer, etc. but this is not
abnormal.
Preparation of heating
(HOT KEEP) display
See page 9.
Temperature setting/time setting switch
This switch is used to set the room
temperature and the timer time.
See page 5.
Return air temperature display
The temperature of return air is
indicated.
Auto swing switch
Activates and stops the swing flap.
See page 6.
Blow rate switch
The fan speed is switched.
Remote display
This display is indicated when the unit is controlled by
the normal individual remote controller.
(The indication remains intact while the air-conditioner
is stopped, too.)
Center display
This display is indicated when the unit
is controlled by the center console that
is sold separately.
Timer operation display
This display indicates the content of
timer operation.
(The indication remains intact while
the air-conditioner is stopped, too.)
Check switch
This switch is used for service.
Timer switch
This switch is used to select the content of timer
operation. See page 5.
Setting switch
This switch is used to set the timer time.
See page 5.
Filter sign
When this display is indicated,
clean the air filter.
See page 6 and 7.
Time display/
indoor unit No. display
Auto swing display
The state of the swing flap is
displayed.
Blow rate display
The fan speed set is displayed.
Setting temperature display
This display indicates the setting
temperature.
Filter reset switch
This switch resets (erases) the filter sign
display.
(Press this switch after the cleaning of
filter has been finished.)
Cover
Mode switch
This switch makes selection of the
operation mode.
N O T E
CHECK
FAN
SPEED
AUTO
SWING
TIMER
SET
MODE
TEMP
TIME
PROGRAMTIMER
SE T TEMP
E
C
LO
HI
FAN
MED
C
Outdoor No.
CENTER REMOTE
AUTODRYCOOLFANHEAT
FILTER
RESET
I
O
O
ON OFF
AM
PM
HOT
KEEP
4
To protect the compressor at the time of starting, turn on the power supply switch 12 hours before starting run.
Moreover, keep the power switch on in the season.
OPERATION PROCEDURE
Request:
1
Press the ON / OFF switch.
The air conditioner starts operating.
To select an operation mode.
Press mode switch to change to AUTO
DRY COOL FAN HEAT .
(The AUTO and HEAT settings are not
included with exclusive cooler units.)
2
Press the ROOM TEMP. switch.
Press or to set the room temperature.
Press the ON / OFF switch.
Stop
The Operation mode, temperature setting and blow rate can be changed during the operation stop as well. When they are
operated during stop, the corresponding display area is indicated for several seconds.
After several seconds since the remote controller is operated, the setting of air-conditioner unit changes.
To operate the air conditioner every day with repetition of run/stop under the same conditions (operation mode, set tempera-
ture, blow rate and auto swing), step 1 ON/OFF alone is sufficient.
The condition previously set is displayed on the remote controller.
Quiet mode or a maximum performance mode on the FDT series can be set with dip switches on the circuit board of the indoor
control unit. (Factory settings differ depending on model.)
Avoid frequent operation of ON and OFF.
Do not use something with a sharp tip to press the remote controller switch.
During raising and lowering of the setting temperature by pressing the temperature setting switch, the
operation of unit may stop. This is caused from the activation of temperature controller and is not a
malfunction.
The air blow rate in the dehumidification operation repeats weak- stop in proportion to the room tem-
perature automatically. The adjustment by the blow rate switch is impossible.
When switching on the power and running the unit for the first time, a temperature of 23°C and the air
flow volume are displayed in the remote control and operation begins at those auto run (exclusive cooler
unit: cooling) settings. Please set the run mode and temperature at a the desired levels.
In the case of automatic operation the [cooling] and [heating] operation are changed over automatically
in proportion to the difference of setting temperature and the room temperature to keep the room tem-
perature constant.
(Combined cooling and heating units only.)
Standard of room temp. setting
Cooling .......................... 26 to 28°C
Dehumidification ............ 21 to 24°C
Heating .......................... 22 to 24°C
Air blowing .....................
Room temp. set is not necessary.
Temperature
controller is
in operation.
Press the FAN SPEED switch.
Fan speed varies in the following sequence.
HI
LO
(In dehumidifying run, fan speed is automatically set.)
Press the AUTO SWING switch.
Effective stop position.
For AUTO.................... Medium
For COOL, DRY .......... Horizontal
For HEATING ............. Downward
Page 6