User manual

Model FD-PAC / FDC140VS
Model
Technical specifications
Control kit Outdoor unit
FD0-PAC FDC140VS
Nominal coolingcapacity (1) W 14000 (5000 ~ 14500)
Nominal heating capacity (1) W 16000 (4000 ~ 16500)
Power source 1 fase, 220/230/240V, 50Hz, N, PE
Operation data (3)
Cooling power consumption kW 4,98/4,98
Running current (cooling) A 22,0/23,0
Power factor (cooling) % 98/98
Heating power consumption kW 4,69/4,69
Running current (heating) A 20,5/21,5
Power factor (heating) % 99
Inrush current A 5,0
Moise level dB(A) - 51
Exterior dimensions (height x width x depth) mm 400 x 300 x 120 845 x 970 x 370
Nett weight Kg 8 74
Compressor type - RM-B5125MD11
Compressor motor kW - 2,6
Refrigerant oil L - 0,9 (M-MA68)
Carterheating W - 20 (carterheating)
Starting method - Direct
Heat exchanger - Air (straight fin)
Defrost control Microprocessor controller de-icer
Refrigerant R410A
Refrigerant amount kg - 3,8 (pre-charged to 30 mtr)
Refrigerant expansion Elektronic expansion valve
Air handling equipment, fan type - Axiaal ventilator x 1
Motor - 120 x 1
Air flow m³/h Min.2000 4500
Air entrance temperature cooling min./ max. °C 16 / 32 -
Air entrance temperature heating min./ max. °C 10 / 32 -
Water entrance temperature cooling min./
max.
°C 16 / 32 -
Water entrance temperature heating min./
max.
°C 10 / 32 -
Safety equipment
-
Internal thermostat for fanmotor,
anomalous discharge temperature
protection
Refrigerant piping mm Liquid line 10mm, Gas line 16mm
Piping size mm Liquid line 9,52 mm (3/8”), Gas line 15,88mm (5/8”)
Connecting method Flare piping
Isolation Necessary (liquid and gasline)
Drain hose mm - Drain pan3x Ø20 mm
Accessoires -
Paneel (separate packing) -
Optional accessoires - -
Remote controller RC-E3 -
Notes
(1) The data are measured at the following conditions.
Item
Mode
Indoor temperature Outdoor temperature
standard
d.b. temp. w.b. temp. d.b. temp. w.b. temp.
Cooling 27°C 19°C 35°C 24°C
ISO-T1, JIS
B8616
Heating 20°C - 7°C 6°C
(2) This airconditioner is manufactured and tested in conformity with the following standards: ISO-T1”unitary
airconditioner”.
(3) The operation data indicate when the airconditioner is operated at 230V, 50hz.
(4) Values in ( ~ ) show the minimum to maximum range.
(5) Adjustment of the estimated output via DIP switch (see page 16).
-9-