Specifications
Up to 96 cells (some cells can have two or 
more indoor units and total number of 
indoor units can be up to 128 units) are 
controlled from the Internet.
Additional engineering service cost is required. 
Please consult your dealer when using this central 
control.
Up to 96 cells (some cells can have two or 
more indoor units and total number of indoor 
units can be up to 128 units) are controlled 
centrally from a BMS.
Additional engineering service cost is required. In case 
of SC-BGWN-B, communication test by qualied 
person regarding electric cost calculation function is 
required before commissioning. Please consult your 
dealer when using this gateway.
Up to 96 indoor units (48 indoor unit x 2) are 
linked as an open network. Centrally 
controlled through LonWorks.
Additional engineering service cost is required. 
Please consult your dealer when using this gateway.
Outdoor unit
Internal/external Crossing
Indoor unit
Remote control
SL E Board
Network
options
X Y 
X Y 
X Y 
A B
A B
Outdoor unit
Internal/external Crossing
Inside
Inside Inside Inside
R R
SL E
Board
Network
options
Outdoor unit
Internal/external Crossing
Inside
Inside Inside Inside
R R
SL E
Board
Outdoor unit
Internal/external Crossing
Inside
Inside Inside
R R
SL E
Board
Network
options
Outdoor unit
Internal/external Crossing
Inside
Inside
SL E
Board
Network
options
Outdoor unit
Internal/external Crossing
Inside
Inside
SL E
Board
Network
options
Wireless Kit
Wireless 
remote control
Basic Connections Plural Controls by Multiple Remote Controls. Mixture of Multiple Units
Plural Controls by Multiple Remote Controls. Mixture of Multiple Units Without Remote Control Wireless Kit
(3) Metal box dimension
85
40
35
30
90 5
100
70
22.5
2-ø6
SUPERLINK E BOARD (SC-ADNA-E)
This board is used when conducting control of the single package (wired remote control unit) 1-type series using a 
network option (SC-SL1N-E, SC-SL2NA-E, etc).
(1) Functions
 (a) Transmits the settings from the network option to the indoor units.
 (b) Returns the priority indoor unit data in response to a data request from the network option.
 (c) Inspects the error status of connected indoor units and transmits the inspection codes to the network option.
 (d) A maximum of 16 units can be controlled (if in the same operation mode).
(2) Wiring connection diagram
Set up “000” to “127” using address switch on the SL E board.
• Transmit the information of plural “Master” units to the network.
• Transmit the abnormalities of the “Slave” units to the network.
 Setting the plural “Master/Slave” units with the dip SW of the printed circuit board.
 Setting the “Master/Slave” remote controls with the dip SW of the remote control board.
Set the SL E board dip SW 
to “Master” SW3-1 ON.
The network option 
SLA-1-E, SL1N-E is not 
allowed (This will disturb 
switching of the operation 
mode)
SC-SL1N-E
SC-ADNA-E
KX6 series
Start/stop control of up to 16 indoor units is 
possible either individually or collectively. With 
simple operations, you can effect centralised 
control.
Centralised control of up to 64 indoor units. 
Allows connection with a weekly timer without 
using any interface.
Easy operation through the large color LCD 
and touch panel. Up to 128 indoor units can be 
controlled, when three SUPERLINK-II systems 
are connected.
SC-SL1N-E
SC-WGWNA-A/B
(SC-WGWNA-B has electric power calculation function)
PC windows central control
SC-BGWN-A/B
(BACnet gateway)
(SC-WGWN-B has electric power calculation function)
BMS interface unit
SC-LGWN-A
(LonWorks gateway)
SC-SL2NA-E
Central Control
SC-SL3N-AE/BE
SC-ADNA-E
RAC series
(SRK/SRF-ZJX-S)
SC-ADNA-E
SC-BIKN-E
Connected to the remote controller terminals (no 
polarity) (the length should be 600 m or shorter)
Connected to the terminals for
Superlink signal lines
MVVS 0.75 - 1.25mm
2
SL E board
OFF
SW3
SW1
LED2
Run
Abnormal
LED3
SW2
ON
A
B
X
Y
X
Y
A
B
Blue
Blue
Black
White
Master/Sub 
address
Network address setting switches 
[000]-(127)
200 m or shorter
300 m or shorter
400 m or shorter
600 m or shorter
0.5 mm
2
 x 2 cores
0.75 mm
2
 x 2 cores
1.25 mm
2
 x 2 cores
2.0 mm
2
 x 2 cores
SC-SL2NA-E
SUPERLINK-SUPERLINK-
21
coNtroL sYstEM