Specifications
4140
FDC100VNX, 100VSX, 125VNX, 125VSX,
140VNX, 140VSX (
unit:mm)
OUTDOOR UNIT DIMENSIONS
Minimum installation space
Intake
outlet
Intake
Service
space
L1
L2
L3
L4
FDC100VN, 125VN, 140VN
100VS, 125VS, 140VS (
unit:mm)
Mark
A
B
C
D
E
F
Item
Refrigerant gas side pipe
connection tap
Refrigerant liquid side pipe
connection tap
Pipe/cable draw-out port
Drain discharge port
Anchor bolt hole
Cable draw-out port
ø15.88(flare)
ø9.52(flare)
ø
20.3x3places
M10x4places
ø
30.3x3places
Notes:
(1) It must not be surrounded by walls on the four sides.
(2) The unit must be fixed with anchor bolts.An anchor
bolt must not protrude more than 15mm.
(3) Where the unit is subject to strong winds, lay it in such
a direction that the blower outlet faces
perpendicularly to the dominant wind direction.
(4) Leave a 1m or larger space above the unit.
(5) A wall in front of the blower outlet must not exceed the
units height.
(6) The unit name plate is attached on the lower right
corner of the front panel.
500
Open
150
5
Open
5
300
5
Open
300
150
5
321
L1
L2
L3
L4
Dimensions
Examples of
installation
A
51
40
36
100
845
10
11050
195
242
279
970
50 15
55
5027
52
11050
195
B
B
A
A
Terminal block
F
C
C
VIEW A
C
5015
7050
150
40
F
E
370 4040
410 2020
55
60
388262
38
60
190 580 200
60 15
103 15
C
D
FDC71VNX (unit:mm)
SRC40ZIX-S, 50ZIX-S, 60ZIX-S (unit:mm)
Mark
A
B
D
E
Item
Refrigerant gas side pipe connection tap
Refrigerant liquid side pipe connection tap
Drain discharge port
Anchor bolt hole
ø12.7(flare)
ø6.35(flare)
ø
20.5x5places
M10x4places
Notes:
(1) It must not be surrounded by walls on the four sides.
(2) The unit must be fixed with anchor bolts.An anchor bolt must not protrude more than
15mm.
(3) Where the unit is subject to strong winds, lay it in such a direction that the blower outlet
faces perpendicularly to the dominant wind direction.
(4) Leave a 1m or larger space above the unit.
(5) A wall in front of the blower outlet must not exceed the units height.
(6) The unit name plate is attached on the lower right corner of the front panel.
280
Open
80
250
280
75
80
Open
Open
100
100
250
321
L1
L2
L3
L4
Dimensions
Examples of
installation
327.3
43.5
290
83.5
24.3312.514.8
351.6
327.3
89 510
800
201
17.9
71.2
E
D
50.6
12
640
12.4
93 42.5
148.4 33.5
40°
40°
Check joint
Te rminal block
B
A
L2
L3
outlet
L1
L4
Intake
Service
space
Intake
C
F
52
27
50
170
50
85
F
C
50
15 50
50
160
70
E
D
C
370
410 2020
40 40
55
60
262 388
38
580190 200
103
15
60 15
60
46
51
46
113
A
B
L1
L3
Intake
Outlet
Intake
Service
space
L2
L4
Te rminal block
C
F
B
A
1300
10
55
1550
970
50
624
612
155
85
35
500
Open
150
5
Open
5
300
5
Open
300
150
5
321
L1
L2
L3
L4
Dimensions
Examples of
installation
Notes:
(1) It must not be surrounded by walls on the four
sides.
(2) The unit must be fixed with anchor bolts. An
anchor bolt must not protrude more than
15mm.
(3) Where the unit is subject to strong winds, lay it
in such a direction that the blower outlet faces
perpendicularly to the dominant wind direction.
(4) Leave 1m or more space above the unit.
(5) A wall in front of the blower outlet must not
exceed the units height.
(6) The model name label is attached on the lower
right corner of the front panel.
(7) Connect the Service valve with local pipe by
using the pipe of the attachment. (Gas side
only)
Item
Service valve connection(liquid side)
Pipe/cable draw-out hole
Drain discharge hole
Anchor bolt hole
Cable draw-out hole
ø15.88(5/8")(Flare)
ø9.52(3/8")(Flare)
ø20x3places
M10x4places
ø30x2places(front)
ø45(side)
ø50(back)
Mark
A
B
C
D
E
F
Service valve connection of the
attached connecting pipe(gas
side)
Minimum installation space
500
Open
100
250
Open
250
150
250
Open
300
100
250
321
L1
L2
L3
L4
Dimensions
Examples of
installation
Mark
A
B
C
D
E
Item
Service valve connection
(gas side)
Service valve connection
(liquid side)
Pipe/cable draw-out hole
Drain discharge hole
Anchor bolt hole
ø15.88(5/8")
(Flare)
M10x4places
ø20x3places
ø9.52(3/8")
(Flare)
Notes:
(1) It must not be surrounded by walls on the four sides.
(2) The unit must be fixed with anchor bolts. An anchor bolt must
not protrude more the 15mm.
(3) Where the unit is subject to strong winds, lay it in such a
direction that the blower outlet faces perpendicularly to the
dominant wind direction.
(4) Leave 1m or more space above the unit.
(5) A wall in front of the blower outlet must not exceed the units
height.
(6) The model name label is attached on the lower right corner of
the front.
165.5 25
Terminal block
B
A
C
30
30
48.5103.5
750
24
Minimum installation space
Intake
outlet
Intake
Service
space
L1
L2
L3
L4
D
E
2-R7.5
27
32
88
880
150580
150
61
310
223
60
15
340
61
47.5
19
380
418