Specifications

3736
Wired remote control with weekly timer (option)
RC-E4 stores operation data when an anomaly occurs and indicates the error
on the LCD. It also displays cumulative operation hours of the air conditioner
and compressor since commissioning.
Run hour meters to facilitate maintenance checking
RC-E4 provides (as a standard feature) a weekly timer, which allows one-
week operation schedules to be registered. A user can specify up to four
times a day to start/stop the air conditioner. (Temperature setting is also
possible with the timer).
Weekly timer function as standard
Room temperature controlled
by the remote control sensor
FDC200VS
(8.0HP)
FDC71VNX
(3.0HP)
FDC250VS
(10.0HP)
Control Systems [Individual control]
OUTDOOR UNIT (1.5-10.0HP)
Installation workability
Enhanced installation workability thanks to the extended pipe length – longest level
in the industry and pre-charged refrigerant.
Refrigerant precharged piping length extends up to 30m. (1.5~2.5HP:15m)
This eliminates the need to add refrigerant on site, which sets it free from trouble of excessive or insufficient charging of refrigerant, and allows
carrying out the installation smoothly.
Point
1
Piping length – 100m
(Hyper Inverter 4~6HP)
Point
2
Refrigerant precharged piping length extending to 30m
RC-E4
Simple remote control (option)
It can control up to 16 units individually, with pressing the AIR CON No. button.
Up to 16 units
This function allows starting the air conditioner automatically when power
supply is restored after power failure or by turning on the power switch.
AUTO restart
RCH-E3 (wired)
Considering specialized usage in hotel
rooms, control buttons are limited only to
minimum required functions such as ON/OFF,
mode, temperature setting and fan speed. It
is really simple and easy to use.
RCH-E3 is not applicable to the Individual flap control
system and the Flap control system.
When RCH-E3 is used, the fan has 3 speed settings (Hi-
Me-Lo) only.
When wireless remote control is used, the fan has 3 speed settings (Hi-Me-Lo) only.
RCN-T-36W-E,
RCN-TC-24W-ER
RCN-KIT3-E RCN-E1R
For wireless control simply insert the infrared
receiver kit on a corner of the panel.
SC-THB-E3
In case sensor in the indoor units or the remote
control sensor can not sense the room temperature
correctly, or individual remote control in each room is
not required but only censor is required (as when
center control system is in place), install SC-THB-E3
at proper place in the rooms.
The RC-E4 controller
enables extensive access to
service and maintenance
technical data combined
with easy to use functions
and a clear LCD display.
Remote Control line up
indoor unit remote control
wired all models
RCH-E3
RC-E4
indoor unit remote control
wireless
RCN-TC-24W-ER
RCN-T-36W-E
FDTC
FDT
RCN-KIT3-EFDUM, FDU
RCN-E1RFDEN
The temperature sensor is housed in the top
section of the remote control unit. This
arrangement has improved the sensitivity of the
remote control unit’s sensor, which permits more
finely controlled air conditioning.
Changeable range
Upper limit 20~30°C(effective for heating operation)
Lower limit 18~26°C(effective for non-heating operation)
RC-E4 allows the upper and lower limits of a set temperature range to be
specified separately.
By adjusting a set temperature range, you can ensure energy saving air
conditioning by avoiding excessive cooling or heating.
Changeable set temperature ranges
Timer operation
Wireless remote control (option) Thermistor (option)
Micro Inverter
Micro Inverter
FDC125VNX
FDC125VSX
(5.0HP)
FDC140VNX
FDC140VSX
(6.0HP)
FDC100VNX
FDC100VSX
(4.0HP)
NEW
SRC40ZIX-S
SRC50ZIX-S
*
SRC60ZIX-S
*
(1.5HP~2.5HP)
*
SRC50/60ZIX-S is common for both of outdoor units of
SRK50/60ZJX-S (Residential Air-conditioners) and 1.5,
2, 2.5HP of Inverter Packaged Air-Conditioners.
Common components make for easy inventory control
and the installation procedure will be the same.
Due to application of blue coated fins (KS101)
for the heat exchanger of new outdoor unit,
corrosion resistance has been improved
compared to current models.
Blue Fin (3~10HP)
This kit is recommended to be used in
an area where the lowest temperature
drops below 0˚C.
Base heater kit (option)
CW-H-E
applied for
FDC100~250VN,VS
FDC100~140VNX,VSX
Height difference
(Outdoor higher than Indoor)
Piping
length
Micro Inverter
HP
1.5~2.5
3
4~6
30m
50m
100m
20m
30m
30m
Piping
length
Height
difference
Height difference
(Outdoor higher than Indoor)
Piping
length
HP
4~6
8
.
10
50m
70m
30m
30m
Piping
length
Height
difference
FDC100VN
FDC125VN
FDC140VN
FDC100VS
FDC125VS
FDC140VS
(4.0HP~6.0HP)
Refer to our Technical Manual in detail