Specifications

22 23
CLASS
A
A
RCN-KIT3-E
(Option)
Wireless remote control
FDUM 100/125/140VD
RC-E4
(Option)
Wired remote control
RCH-E3
(Option)
Filter kit
UM-FL3E : for 100, 125, 140
(option)
external static pressure loss:5pa
Set model name
Indoor name
Outdoor name
Power source
Nominal cooling capacity
(Min~Max)
Nominal heating capacity
(Min~Max)
Power Consumption
COP
Energy label
Inrush current (Max. running current)
Sound Ievel
*
1
Air flow
Static pressure
Exterior dimensions
Net weight
Air filter, Q'ty
Remote control(option)
ISO-T1(JIS)
ISO-T1(JIS)
Cooling/Heating
Cooling/Heating
Cooling/Heating
Indoor
Outdoor
Indoor
Outdoor
Height x Width x Depth
kW
kW
kW
A
dB(A)
CMM
Pa
mm
kg
mm
kg
kg(m)
ø
m
m
m
O/U
O/U
SPECIFICATIONS
Indoor unit
Outdoor unit
Range of
usage
FDUM100VNVD
FDUM100VD
FDC100VN
FDUM125VNVD
FDUM125VD
FDC125VN
FDUM140VNVD
FDUM140VD
FDC140VN
1Phase 220-240V 50Hz, 1Phase 220V 60Hz
10.0
(4.0~11.2)
11.2
(4.0~12.5)
50Hz:2.80/2.77
60Hz:2.80/2.80
50Hz:3.57/4.04
60Hz:3.57/4.00
A/A
12.5
(5.0~14.0)
14.0
(4.0~16.0)
50Hz:4.03/3.80
60Hz:4.03/3.85
50Hz:3.10/3.68
60Hz:3.10/3.64
B/A
5(24)
Cooling:50 Heating:51
14.0
(5.0~14.5)
16.0
(4.0~16.5)
50Hz:4.95/4.89
60Hz:4.95/4.91
50Hz:2.83/3.27
60Hz:2.83/3.26
C/C
51
FDUM100VSVD
FDUM100VD
FDC100VS
FDUM125VSVD
FDUM125VD
FDC125VS
3Phase 380-415V 50Hz, 3Phase 380V 60Hz
FDUM140VSVD
FDUM140VD
FDC140VS
10.0
(4.0~11.2)
11.2
(4.0~12.5)
50Hz:2.80/2.77
60Hz:2.80/2.80
50Hz:3.57/4.04
60Hz:3.57/4.00
A/A
12.5
(5.0~14.0)
14.0
(4.0~16.0)
50Hz:4.03/3.80
60Hz:4.03/3.85
50Hz:3.10/3.68
60Hz:3.10/3.64
B/A
5(15)
Cooling:50 Heating:51
14.0
(5.0~14.5)
16.0
(4.0~16.5)
50Hz:4.95/4.89
60Hz:4.95/4.91
50Hz:2.83/3.27
60Hz:2.83/3.26
C/C
51
The data are measured under the following conditions(ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB. External static pressure
of indoor units is 60Pa.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
Hi:38 Me:36 Lo:33Hi:38 Me:36 Lo:33
Hi:37 Me:35 Lo:32
49
Standard:60/55, Max:85/100
Hi:37 Me:35 Lo:32
49
Standard:60, Max:90/100 Standard:60, Max:90/100
Standard:60/55, Max:85/100
Hi:28 Me:25 Lo:22
81 83
Cooling
Heating
O/U is higher
O/U is lower
Operating
temperature range
Ref.piping length
Vertical height
difference
Exterior dimensions
Net weight
Type of compressor
Ref.amount precharged
Ref.piping size
Height x Width x Depth
Liquid/Gas
Cooling:75 Heating:73
Powerful-Hi can be selected. Sound level: 100/125/140VNVD 41dB, 100/125/140VSVD 41dB
Air flow: 100/125/140VNVD 34CMM, 100/125/140VSVD 34CMM
CLASS
A
A
FDEN 100/125/140VD
RCN-E1R
(Option)
Wireless remote control
RC-E4
(Option)
Wired remote control
RCH-E3
(Option)
ISO-T1(JIS)
ISO-T1(JIS)
Cooling/Heating
Cooling/Heating
Cooling/Heating
Indoor
Outdoor
Indoor
Outdoor
Height x Width x Depth
kW
kW
kW
A
dB(A)
CMM
mm
kg
mm
kg
kg(m)
ø
m
m
m
O/U
O/U
FDEN125VNVD
FDEN140VNVD
SPECIFICATIONS
Indoor unit
Outdoor unit
Range of
usage
1Phase 220-240V 50Hz, 1Phase 220V 60Hz
12.5
(5.0~14.0)
14.0
(4.0~16.0)
4.45/4.08
2.80/3.43
C/B
5(24)
14.0
(5.0~14.5)
16.0
(4.0~16.5)
5.80/4.92
2.41/3.25
E/C
250x1,620x690
49
FDEN100VNVD
FDEN125VD
FDC125VN
FDEN140VD
FDC140VN
FDEN100VD
FDC100VN
10.0
(4.0~11.2)
11.2
(4.0~12.5)
2.85/2.97
3.51/3.77
A/A
FDEN100VSVD FDEN125VSVD
3Phase 380-415V 50Hz, 3Phase 380V 60Hz
FDEN140VSVD
FDEN100VD
FDC100VS
FDEN125VD
FDC125VS
FDEN140VD
FDC140VS
10.0
(4.0~11.2)
11.2
(4.0~12.5)
2.85/2.97
3.51/3.77
A/A
12.5
(5.0~14.0)
14.0
(4.0~16.0)
4.45/4.08
2.80/3.43
C/B
5(15)
14.0
(5.0~14.5)
16.0
(4.0~16.5)
5.80/4.92
2.41/3.25
E/C
The data are measured under the following conditions(ISO-T1).
Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB.
Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB.
*
1 : Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions.
*
2 : If a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural
wind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down.
Set model name
Indoor name
Outdoor name
Power source
Nominal cooling capacity
(Min~Max)
Nominal heating capacity
(Min~Max)
Power Consumption
COP
Energy label
Inrush current (Max. running current)
Sound Ievel
*1
Air flow
Exterior dimensions
Net weight
Air filter, Q'ty
Remote control(option)
Hi:46 Me:44 Lo:43 Hi:46 Me:44 Lo:43
Operating
temperature range
Cooling
Heating
O/U is higher
O/U is lower
Ref.piping length
Vertical height
difference
Exterior dimensions
Net weight
Type of compressor
Ref.amount precharged
Ref.piping size
Height x Width x Depth
Liquid/Gas
50
30
15
-15~43
*
2
-20~20
Rotary
3.8(30)
9.52/15.88
845x970x370
81 83
Hi:44
Me:41 Lo:39
49
Hi:26
Me:23 Lo:21
Cooling:50 Heating:51
Pocket Plastic net x2 (Washable)
Wired:RC-E4, RCH-E3 Wireless:RCN-E1R
51
Hi:44
Me:41 Lo:39
49
Hi:26
Me:23 Lo:21
Cooling:50 Heating:51
51
Cooling:75 Heating:73
Hi:29 Me:26 Lo:23 Hi:29 Me:26 Lo:23
Powerful-Hi can be selected. Sound level: 100VNVD 46dB, 125/140VNVD 50dB, 100VSVD 46dB, 125/140VSVD 50dB
Air flow: 100VNVD 28CMM, 125/140VNVD 32CMM, 100VSVD 28CMM, 125/140VSVD 32CMM
FDUM FDEN
CEILING SUSPENDEDDUCT CONNECTED -Low/Middle Static pressure-
Micro Inverter
Micro Inverter
350x1,370x635
59
Procure locally
Wired:RC-E4, RCH-E3 Wireless:RCN-KIT3-E
845x970x370
Rotary
3.8(30)
9.52/15.88
50
30
15
-15~43*
2
-20~20
[ INDOOR UNIT ]
Micro Inverter